C-Series
[Applied Models]
zInverter Multi : Cooling Only
zInverter Multi : Heat Pump
Si12 - 411A

Table of Contents

Other manuals for Daikin 4MXS68BVMB9

Questions and Answers

  • M
    Maureen RogersAug 20, 2025
    What to do if my Daikin Air conditioning does not operate and the OPERATION lamp is off?
    • D
      Donna HaleAug 20, 2025
      If your Daikin air conditioner isn't operating and the OPERATION lamp is off, check the following: Has a breaker turned OFF or a fuse blown? Is there a power failure? Are batteries properly set in the remote controller? Is the timer setting correct?
  • N
    nfrostAug 22, 2025
    What to do if Daikin 4MXS68BVMB9 operation stops suddenly and the OPERATION lamp flashes?
    • C
      Charles WalkerAug 22, 2025
      If the Daikin air conditioning stops suddenly and the OPERATION lamp flashes, clean the air filters or remove any obstacles. Then, turn the breaker OFF, turn it ON again, and try operating the air conditioner with the remote controller.
  • E
    Emily RyanAug 25, 2025
    What to do if water leaks from the indoor unit of Daikin 4MXS68BVMB9 Air conditioning?
    • J
      Jacob BeckerAug 25, 2025
      If water leaks from the indoor unit, turn the breaker OFF and call the service shop.
  • A
    Ashley PenningtonAug 27, 2025
    Why my Daikin 4MXS68BVMB9 Air conditioning operation does not start soon?
    • J
      jhunterAug 27, 2025
      You should wait for about 3 minutes.
  • D
    Dillon MontesAug 28, 2025
    What to do if I hear an abnormal sound during Daikin 4MXS68BVMB9 Air conditioning operation?
    • E
      ericwellsAug 28, 2025
      If you hear an abnormal sound during operation, turn the breaker OFF and call the service shop.
  • Q
    qwilliamsAug 30, 2025
    What to do if there is a burning smell coming from Daikin 4MXS68BVMB9 Air conditioning?
    • J
      Jennifer RichardsonAug 30, 2025
      If you notice a burning smell, immediately turn the breaker OFF and call the service shop.
  • L
    Lynn KennedySep 1, 2025
    What to do if an abnormality (such as a burning smell) occurs with Daikin 4MXS68BVMB9?
    • R
      Rachel LiuSep 1, 2025
      If an abnormality, such as a burning smell, occurs, turn the breaker OFF and call the service shop.
  • M
    Mitchell SmithSep 3, 2025
    How to stop the bad odor from my Daikin 4MXS68BVMB9 Air conditioning indoor unit?
    • S
      Stephanie ReyesSep 3, 2025
      If the indoor unit gives out an odor, it is recommended to have the indoor unit washed by a technician. Consult the service shop where you bought the air conditioner.
  • J
    Jennifer RubioSep 5, 2025
    Why is my Daikin 4MXS68BVMB9 Air conditioning cooling/heating effect poor?
    • R
      Rhonda RodriguezSep 5, 2025
      The cooling or heating effect might be poor due to several reasons. Check if the air filters are clean. Ensure there is nothing blocking the air inlet or outlet of the indoor and outdoor units. Verify that the temperature setting is appropriate. Make sure the windows and doors are closed. Confirm that the airflow rate and direction are set correctly. Also, check if the unit is set to INTELLIGENT EYE mode.
  • R
    Richard MunozSep 7, 2025
    What to do if the power cord of Daikin Air conditioning is abnormally hot or damaged?
    • D
      Daniel DavisSep 7, 2025
      If the power cord is abnormally hot or damaged, turn the breaker OFF and call the service shop.

Summary

1. Introduction

1.1 Safety Cautions

Essential safety precautions and warnings for handling and repairing the air conditioner.

1.1.1 Caution in Repair

Specific warnings and precautions to be observed during repair work to prevent hazards.

1.1.2 Cautions Regarding Products after Repair

Part 1 List of Functions

Part 2 Specifications

Part 3 Printed Circuit Board Connector Wiring Diagram

Part 4 Function and Control

Part 5 System Configuration

Part 6 Service Diagnosis

1. Caution for Diagnosis

Important cautions to observe before performing diagnostic procedures.

1.1 Troubleshooting with the Operation Lamp

Using the operation lamp indicators for basic troubleshooting.

2. Problem Symptoms and Measures

Common operational problems and their recommended solutions.

4. Code Indication on the Remote Controller

Explanation of error codes displayed on the remote controller.

4.1 Error Codes and Description of Fault

Detailed list of error codes and their corresponding fault descriptions.

5. Troubleshooting

Comprehensive guide to diagnosing and resolving system issues.

5.1 Indoor Units

Troubleshooting steps specific to indoor unit malfunctions.

5.2 Outdoor Units

Troubleshooting steps specific to outdoor unit malfunctions.

Part 7 Removal Procedure

1.10 Removal of Compressor

Detailed procedure for removing the compressor.

2. Outdoor Unit (50; 52; 58; 68; 75 Class)

Procedure for removing external panels and components from larger outdoor units.

2.9 Removal of Compressor

Detailed procedure for removing the compressor from larger units.

Daikin 4MXS68BVMB9 Specifications

General IconGeneral
Model4MXS68BVMB9
Maximum Height Difference15 m
Power Supply220-240V, 50Hz
RefrigerantR32
Indoor Unit Dimensions (WxHxD)Data varies depending on the indoor unit model. Please refer to the specifications of the chosen indoor unit.
Air Flow (Indoor Unit)Data varies depending on the indoor unit model. Please refer to the specifications of the chosen indoor unit.