EasyManua.ls Logo

Daikin AKZ568 - User Manual

Daikin AKZ568
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Built-in breaker
model
Built-in tank
model
Different-voltage
model
CE model
Built-in heater
model
Installation
Models
Oil Cooling Unit and Accessories
4
Precautions for Installation 5
Reference for Pipe Selection 6
Electric Wiring 7
CONTENTS
1
Circulating type
Standard
model
Menu
Series
Built-in
breaker
model (–B)
CE model
(–C)
Built-in
heater
model (–H)
Built-in
tank model
(–T1, –T)
Different-
voltage
model (–E)
AKZ148
AKZ328
AKZ438
AKZ568
AKZ908
Instruction Manual
AKZ8 Series
If the air filter is clogged, the cooling performance deteriorates,
causing excess power consumption.
Clean the air filter periodically to reduce power consumption.
Thank you for purchasing DAIKIN Oil Cooling Unit (“OILCON”).
This instruction manual includes instructions for using the Oil
Cooling Unit.
To ensure proper use of this product, be sure to read through this
instruction manual before using it.
After reading this manual, keep it handy for your future reference.
Monitor Items 23
Timer Operation 24
Additional Setting Functions 25
Setting Additional Function 27
For Temperature Control Improvement 30
Alarm/Warning Output Logic 33
Alarm Settings for Optional Protection
Devices (Installed by User) 33
Handling
Before Operation
12Model Identification and Specifications
14
Part Names and Functions 15
Names and Functions of the Control Panel Parts
16
Checking Initial Operating Conditions 18
Operation Setting 19
Holding Constant Oil Temperature 20
Tuning Oil Temperature to Room Temperature
(or Machine Temperature)
21
Cooling Oil at Constant Capacity (%) 22
Optional Parts
Machine temperature tuning control 34
Returned oil temperature control 35
Communication with main machine 36
Maintenance
37
38
Maintenance/Inspection
• Daily maintenance/inspection
• Periodic maintenance/inspection
To leave the unit unused for a long period
Troubleshooting
When the unit operation seems abnormal
although no alarm is activated
When an alarm is activated
Safety Precautions
Installation
Procedure
Before
Operation
Useful
Functions
Maintenance
Troubleshooting
Optional
Functions
Operating
Procedure
DAIKIN Oil Cooling Unit
(“OILCON”)
Proper use results in power saving
PIM00116C
PIM00116C_EN.fm -1 ペー 00  

Questions and Answers

  • A
    annettenielsenAug 6, 2025
    What to do if my Daikin AKZ568 unit won't cool oil, even though the pump and compressor are running?
    • M
      Mr. Thomas SimpsonAug 6, 2025
      If your Daikin Accessories unit isn't cooling oil despite the pump and compressor running, several factors could be the cause. First, check for any obstructions near the air intake/exhaust port and remove them. Next, inspect the air filter for clogs and clean it if necessary. Also, the unit might be under capacity suppressing control due to high room temperature; compare the capacity in the operating temperature range with the catalog to see if you need a model with more appropriate capacity. Ensure that the temperature setting isn't too high by adjusting it to a more appropriate level. Finally, if the exhaust air temperature is nearly the same as the room temperature when the compressor is running, the refrigerant gas might be low, and you should refill it.
  • J
    Jon GibsonAug 10, 2025
    What to do if my Daikin AKZ568 compressor does not run, although the pump is running?
    • H
      Holly PerezAug 10, 2025
      If the compressor in your Daikin Accessories unit isn't running while the pump is, it could be due to several reasons. The compressor might be stopped under temperature control. Check if the compressor restart prevention timer has been activated and wait for the preset time to elapse. Also, the low oil temperature or low ambient temperature protection device might be activated; ensure the oil temperature is at least 5°C and the room temperature is at least 0°C. Another possibility is that the capacity setting is at 0% (Mode 9); if so, change the operation mode to an appropriate setting.
  • A
    Anthony CoxAug 15, 2025
    What to do if oil does not flow in my Daikin Accessories, although the pump is running?
    • N
      Nicholas LewisAug 15, 2025
      If oil isn't flowing in your Daikin Accessories unit even when the pump is running, and the pump sound level is high, there are a few things to check. First, inspect the pump suction pipe connection for looseness; check the pipe packing and re-tighten it securely. Then, examine the suction strainer for clogs and clean it; if the oil in the tank is dirty, replace it. Also, check the oil level in the tank and refill if necessary. If there's a large pressure loss in the oil discharge pipe, causing the pump relief valve to activate, increase the oil pipe diameter and shorten the pipe length.
  • E
    Erik CastilloAug 18, 2025
    How to fix Daikin AKZ568 Accessories when operation setting cannot be performed?
    • D
      Daniel RandallAug 18, 2025
      If you cannot perform operation settings on your Daikin Accessories unit, there are a couple of things to check. If “---” appears on the data display, the temperature sensor corresponding to the selected operation mode might not be connected; ensure the corresponding temperature sensor is connected. If “---” momentarily appears when you press the [ENT] key, the erroneous operation prevention switch might be set to ON; turn OFF the erroneous operation prevention switch (SW1) on the control board.
  • D
    David MaloneAug 23, 2025
    Why Daikin AKZ568 alarm output operation is different from conventional signal output?
    • E
      Elizabeth GarciaAug 23, 2025
      The alarm output operation in your Daikin Accessories unit might differ from conventional signal outputs because the alarm output signal connection has been partially changed. The [60] to [63] outputs are compatible with conventional models (AKS5 and AKZ6 series). However, with the AKZ8 series, signal operations and connections of the [64] and [65] outputs have been changed.
  • S
    Stacey MortonAug 27, 2025
    What to do if my Daikin AKZ568 pump does not run?
    • K
      Kristin HarringtonAug 27, 2025
      If the pump in your Daikin Accessories unit isn't running, check the connection of the remote control input. Also, the unit might be set to the operation lock mode; cancel the LOCK mode on the control panel.
  • C
    Cassandra EvansAug 31, 2025
    What to do if my Daikin AKZ568 unit does not run at all?
    • A
      amy04Sep 1, 2025
      If your Daikin Accessories unit isn't running at all and the POWER lamp on the control panel is unlit, check if the main power supply is OFF or if the power cable (L1, L2) is disconnected. Ensure the power cable is connected to the power supply terminal.

Daikin AKZ568 Specifications

General IconGeneral
BrandDaikin
ModelAKZ568
CategoryAccessories
LanguageEnglish

Related product manuals