EasyManua.ls Logo

Daikin ATXB35C2V1B User Manual

Daikin ATXB35C2V1B
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
DAIKIN ROOM AIR CONDITIONER
OPERATION MANUAL
MODELS
ATXB25C2V1B
ATXB35C2V1B

Other manuals for Daikin ATXB35C2V1B

Questions and Answers:

Daikin ATXB35C2V1B Specifications

General IconGeneral
TypeAir conditioner indoor unit
Ionizer-
Multi-splitYes
Product colorWhite
Compressor typeRotary
Gas hose diameter9.5 mm
Hose length (max)15 m
Drain hose diameter18 mm
Liquid hose diameter6.35 mm
Refrigerating mediumR410A
Cooling capacity (max)13000 BTU/h
Cooling capacity (min)4400 BTU/h
Heating capacity (max)16300 BTU/h
Timer duration (maximum)24 h
Air conditioner functionsCooling, Dehumidifying, Fan, Heating
Cooling capacity in watts (max)3800 W
Cooling capacity in watts (min)1300 W
Heating capacity in watts (max)4800 W
Cooling capacity in watts (nominal)3300 W
Cooling energy efficiency (EER, W/W)3.21
Heating energy efficiency (COP, W/W)3.71
Operating temperature (cooling) (T-T)-10 - 46 °C
Operating temperature (heating) (T-T)-15 - 18 °C
Seasonal efficiency rating (cooling) (SEER)6.02
Heating capacity in watts (nominal) (Warmer heating season)- W
Heating capacity in watts (nominal) (Average heating season)3500 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)4.04
Current1 A
AC input voltage220 - 240 V
AC input frequency50 Hz
Design load (cooling)3.3 kW
Power consumption (cooling) (max)1030 W
Power consumption (heating) (max)940 W
Annual energy consumption (cooling)192 kWh
Hourly energy consumption (cooling)- kWh
Design load (heating) (Warmer heating season)- kW
Design load (heating) (Average heating season)2.8 kW
Energy efficiency class (heating) (Average heating season)A+
Annual energy consumption (heating) (Average heating season)970 kWh
Indoor unit typeWall-mountable
Indoor unit depth216 mm
Indoor unit width770 mm
Indoor unit height283 mm
Indoor unit weight8000 g
Indoor units quantity1
Cooling airflow (indoor unit)462 m³/h
Heating airflow (indoor unit)504 m³/h
Indoor unit noise level (low speed)23 dB
Indoor unit noise level (high speed)58 dB
Outdoor unit noise level- dB

Summary

Safety Precautions

Names of Parts

Indoor Unit

Identifies components of the indoor unit including filters, sensors, and outlets.

Outdoor Unit

Identifies components of the outdoor unit, such as air inlets, outlets, and piping.

Preparation before Operation

To set the batteries

Steps for inserting batteries into the remote controller.

To operate the remote controller

Guidelines for aiming the remote controller transmitter at the indoor unit.

To fix the remote controller holder on the wall

Instructions for mounting the remote controller holder securely on a wall.

AUTO DRY COOL HEAT FAN Operation

To start operation

How to select and begin operating the air conditioner using the remote.

To stop operation

How to turn off the air conditioner using the ON/OFF button.

To change the temperature setting

Adjusting the desired temperature for cooling or heating.

Adjusting the Airflow Direction

To start auto swing

Initiating automatic swinging of the horizontal flap for air distribution.

To set the flap at desired position

Stopping the flap at a specific angle while in auto swing mode.

To adjust the louvers (vertical blades)

Manual adjustment of the vertical louvers for directional airflow.

COMFORT AIRFLOW Operation

To start COMFORT AIRFLOW operation

Activating the mode for gentle, indirect airflow.

To cancel COMFORT AIRFLOW operation

Deactivating the COMFORT AIRFLOW mode.

POWERFUL Operation

To start POWERFUL operation

Engaging the mode for maximum cooling or heating effect.

To cancel POWERFUL operation

Disengaging the POWERFUL operation mode.

ECONO Operation

To start ECONO operation

Activating the energy-saving mode to limit power consumption.

To cancel ECONO operation

Deactivating the ECONO operation mode.

OFF TIMER Operation

To use OFF TIMER operation

Instructions for setting the timer to automatically switch the unit off.

To cancel OFF TIMER operation

Cancelling a previously set OFF timer.

ON TIMER Operation

To use ON TIMER operation

Instructions for setting the timer to automatically switch the unit on.

To cancel ON TIMER operation

Cancelling a previously set ON timer.

To combine ON TIMER and OFF TIMER

Using both ON and OFF timers simultaneously for scheduled operation.

Care and Cleaning

Indoor unit and remote controller

Instructions for wiping the indoor unit and remote controller with a dry cloth.

Front panel

Procedures for opening, removing, and cleaning the front panel of the indoor unit.

Filters

Guidance on cleaning and replacing the air filters and air-purifying filters.

Troubleshooting

Related product manuals