EasyManua.ls Logo

Daikin ATXV25AV1B User Manual

Daikin ATXV25AV1B
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
R410A Split Series
MODEL
FTXV25AV1B
FTXV35AV1B
FTXV50AV1B
FTXV60AV1B
RXV25AV1B
RXV35AV1B
RXV50AV1B
RXV60AV1B
ATXV25AV1B
ATXV35AV1B
ATXV50AV1B
ATXV60AV1B
ARXV25AV1B
ARXV35AV1B
ARXV50AV1B
ARXV60AV1B
OWNER'S MANUAL

Other manuals for Daikin ATXV25AV1B

Question and Answer IconNeed help?

Do you have a question about the Daikin ATXV25AV1B and is the answer not in the manual?

Daikin ATXV25AV1B Specifications

General IconGeneral
TypeAir conditioner indoor unit
Ionizer-
Multi-splitNo
Product colorWhite
Inverter technologyYes
Refrigerating mediumR410A
Cooling capacity (max)9042 BTU/h
Heating capacity (max)9554 BTU/h
Timer duration (maximum)24 h
Air conditioner functionsCooling, Heating
Refrigerating medium weight800 g
Cooling capacity in watts (nominal)2650 W
Cooling energy efficiency (EER, W/W)2.98
Heating energy efficiency (COP, W/W)3.11
Seasonal efficiency rating (cooling) (SEER)5.6
Heating capacity in watts (nominal) (Average heating season)2800 W
Seasonal efficiency rating (heating) (SCOP) (Average heating season)3.8
AC input voltage220 V
AC input frequency50 Hz
Energy efficiency class (cooling)A+
Annual energy consumption (cooling)166 kWh
Hourly energy consumption (cooling)0.89 kWh
Hourly energy consumption (heating)0.9 kWh
Energy efficiency class (heating) (Average heating season)A
Annual energy consumption (heating) (Average heating season)1032 kWh
Indoor unit typeWall-mountable
Indoor unit depth180 mm
Indoor unit width845 mm
Indoor unit height275 mm
Indoor unit weight9000 g
Indoor units quantity1
Indoor unit noise level (high speed)54 dB

Summary

Safety Precautions

WARNING and CAUTION Notices

Defines classifications for safety warnings and their potential consequences.

General Installation Safety Warnings

Covers critical safety measures for electrical, refrigerant, and physical installation.

Specific Cautionary Measures

Installation Dimension Requirements

Installation Preparation

Electrical Connection Requirements

Electrical Safety Precautions

Outlines essential safety rules for electrical connections.

Grounding and Circuit Breaker Requirements

Details the importance of proper grounding and earth leakage breaker installation.

Indoor Unit Installation Steps

Outlet Pipe Routing and Connection

Drain Hose and Indoor Unit Wiring

Indoor Unit Power Connection

Pipe Binding and Unit Mounting

Outdoor Unit Installation Steps

Connecting Indoor and Outdoor Refrigerant Pipes

Outdoor Unit Piping and Drain Hose Management

System Checks Post-Installation

Vacuum Pumping Procedure

Outlines the steps for vacuum pumping the refrigerant circuit.

Refrigerant Leakage Detection

Explains methods to check for refrigerant leaks using detectors or soap water.

Final Installation Checks and Operation

Post-Installation Verification

Lists essential checks to confirm correct installation before operation.

Initial Test Operation

Guides on performing the first operational test of the air conditioner.

Refrigerant Pipe Configuration

Refrigerant Pipe Expansion Method

Emergency Operation and Cleaning

Indoor Unit Air Filter Cleaning

Troubleshooting Common Malfunctions

Remote Signal and Airflow Issues

Addresses problems with remote control signals and lack of air emission.

Unit Operation and Temperature Malfunctions

Odor, Noise, and Vapor Malfunctions

Error Code Identification and Solutions

Wiring and Electrical Connections

Wiring Diagram and Wire Color Codes

Related product manuals