Troubleshooting Si10-417
28 Service Diagnosis
(R1946)
Check No. 16
Check hall IC
Is there
an output?
Is it at the
rated voltage?
Check the fan motor voltage.
NO
NO
YES
YES
Replace the fan motor
or indoor unit PCB.
Replace indoor unit
PCB (1).
Replace the fan
motor.