Wiring Diagrams Si12-411A
280 Appendix
4MXS80CVMA
ROOM D
ROOM C
ROOM B
ROOM A
TO INDOOR UNIT
3
3
3
3
2
2
2
2
1
1
1
1
FIELD WIRING
V2~V5 : VARISTOR
MRC/W : MAGNETIC RELAY
MRB
,
MRD
S2~S102 : CONNECTOR
E
,
AC1
,
AC2
L2
,
: CONNECTOR
HE
,
HL
,
HN
Y1E~Y4E : ELECTRONIC EXPANSION VALVE COIL
R1T~R12T : THERMISTOR
H1P~H5P : PILOT LAMP
Z1C~Z3C : FERRITE CORE
MRM10
,
MRM20
X1M~X5M : TERMINAL STRIP
H1
,
H2
,
L1
FU1
,
FU2. FU201 : FUSE
X5M
X4M
X3M
X2M
X1M
L
3
3
3
3
2
2
2
2
N
1
1
1
1
GRN
30A
FU1
YLW
SA1
MID1
V3
Z3C
HE
1
7
HL
S11
HN
GRN
WHT
WHT
WHT
WHT
RED
BLK
YLW
AC2
AC1
H5P
1
E
1
S2W
S10
S15
BLU
V2
BLU
H4P
7
1
5
1
BLU
BLU
H3P
S5W
S51
S52
BLU
BLU
N : NEUTRAL
S3W : WIRING ERROR CHECK SW
(
SW3
)
S4W : PRIORITY ROOM SETTING SW
(
SW4
)
S5W : NIGHT QUIET MODE SETTING SW
(
SW5
)
S2W : FORCED OPERATION MODE SELECT SW
(
SW2
)
L : LIVE
H2P
PCB : PRINTED CIRCUIT BOARD
DB1 : DIODE BRIDGE
S1W : FORCED OPERATION ON/OFF SW
(
SW1
)
L1R : REACTOR
SA1 : SURGE ARRESTER
Y1S : DEFROST SOLENOID VALVE COIL
Y1R : REVERSING SOLENOID VALVE COIL
M1F : FAN MOTOR
CT1 : CURRENT TRANSFORMER
M1C : COMPRESSOR MOTOR
Q1L : OVERLOAD PROTECTOR
BLU
BLU
S1W
H1P
BLU
BLU
BLU
12
S2
12
BLU
S3W
1
1
RED
S102
S101
BLK
V5
S4W
WHT
5
5
GRN
MRM20
MRM10
FU2
3.15A
MRB
1
MRD
Y1S
BLU
MRC W
Y1R
BLK
S80
CT1
BLU
9
BLK
H2
H1
S91
1
WHT
YLW
BLU
t°
SPM : SYSTEM POWER MODULE
MID1~MID2 : MOLDED INTER CONNECT DEVICE
YLW
Y1E
S20
R12T
1
M
A
ORG
BLK
Z2C
BLU
3
BRN
6
RED
1
WHT
~
DB1
~
1
BLK
YLW
+
-
Y2E
S21
BLK
M
B
ORG
BLK
BLU
BLK
RED
PCB
BLK
BRN
5
6
BLK
RED
S32
1
CN11
WHT
5
YLW
1
Y3E
S22
+
-
M
C
ORG
ORG
L1
1
1
BLU
BLK
BRN
BLK
6
SPM
RED
BLK
TERMINALS OF THE COMP.
ASSIGNMENTS OF
BLK
CN14
1
WHT
BLK
ORG
L2
YLW
BLK
Y4E
S23
L1R
Z1C
V
M
D
ORG
BLK
BLU
BLK
P2
W
9
N1
P1
U
W
V
U
BRN
BLK
6
10
(
OUTDOOR
)
RED
S31
N
R3T
1
(
CONDENSER
)
BLU
MID2
TB6
t°
TB4
TB5
P2
N1
P1
R2T
S90
GRY
1
1
(
DISCHARGE
)
WHT
t°
+
R1T
S6
ORG
BLK
6
BRN
t°
S71
+
S72
1
BLU
+
(
ROOM-A
)
FU201
3.15A
R8T
1
(
ROOM-B
)
BLK
8
8
RED
t°
R9T
(
GAS PIPE
)
GRY
1
1
S92
S70
BRN
t°
(
ROOM-C
)
8
R10T
W
V
U
N
1
7
BRN
(
ROOM-D
)
t°
RED
R11T
S33
RED
S34
8
t°
YLW
WHT
BRN
BLU
ORG
RED
RED
BRN
BLU
(
ROOM-A
)
YLW
R4T
1
BLK
(
LIQUID PIPE
)
(
ROOM-B
)
X11A
t°
10
10
R5T
BLU
GRY
3D046413A
S93
t°
YLW
BRN
BLU
RED
R6T
1
YLW
(
ROOM-C
)
GRY
V
S40
t°
(
ROOM-D
)
R7T
1
3
M1F
BLU
M1C
M
M
BLK
4
W
U
t°
Q1L
BLK
9
N

Table of Contents

Other manuals for Daikin CDKD60CVM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin CDKD60CVM and is the answer not in the manual?

Daikin CDKD60CVM Specifications

General IconGeneral
BrandDaikin
ModelCDKD60CVM
CategoryAir conditioning
LanguageEnglish

Related product manuals