SERVICING
35
SUBCOOLING
LIQUID PRESSURE
AT SERVICE VALVE (PSIG) 8 10 12 14 16 18
189 585654525048
195 605856545250
202 626058565452
208 646260585654
215 666462605856
222 686664626058
229 706866646260
236 727068666462
243 747270686664
251 767472706866
259 787674727068
266 807876747270
274 828078767472
283 848280787674
291 868482807876
299 888684828078
308 908886848280
317 929088868482
326 949290888684
335 969492908886
345 989694929088
354 100 98 96 94 92 90
364 102 100 98 96 94 92
374 104 102 100 98 96 94
384 106 104 102 100 98 96
395 108 106 104 102 100 98
406 110 108 106 104 102 100
416 112 110 108 106 104 102
427 114 112 110 108 106 104
439 116 114 112 110 108 106
450 118 116 114 112 110 108
462 120 118 116 114 112 110
474 122 120 118 116 114 112
486 124 122 120 118 116 114
499 126 124 122 120 118 116
511 128 126 124 122 120 118
REQUIRED SUBCOOLING TEMPERATURE (°F)
REQUIRED LIQUID LINE TEMPERATURE
LIQUID PRESSURE
AT ACCESS FITTING (PSIG)