SYSTEM OPERATION
DIP SWITCH SETTINGS
PCBBF137 PCBBF139 DM96VE0603AN - COOLING
DIP Sw itches
S2-1 S2-2 S3-3
DIP Sw itches
S1-1 S1-2 S1-3
Static
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Tstat Call CFM CFM CFM CFM CFM CFM CFM CFM
ON ON OFF / OFF ON ON ON ON OFF
Ylo
Y
1056 1026 991 961
ON OFF OFF ON OFF OFF
Ylo
508 460 419 371
Y
**OFF OFF OFF **OFF OFF OFF
Ylo
880 838 794 763
Y
697 654 600 557
722 689 644 606
OFF OFF ON OFF OFF ON
Ylo
Y
OFF ON OFF^ OFF ON OFF^
Ylo
880 838 794 763
Y
722 689 644 606
880 838 794 763 722 689 644 606
ON ON ON^ ON ON ON^
Ylo
Y
697 654 600 557
ON OFF ON ON OFF ON
Ylo
Y
NA OFF ON ON^
Ylo
697 654 600 557
1330 1301 1274 1244
Y
880 838 794 763 722 689 644 606
1056 1026 991 961 929 894 864 829
697 654 600 557 508 460 419 371
929 894 864 829
1056 1026 991 961 929 894 864 829
12 2 7 119 1 116 3 113 2
13 3 0 13 0 1 12 7 4 12 4 4 12 2 7 119 1 1163 113 2
508 460 419 371
12 2 7 119 1 116 3 113 2
508 460 419 371
12 5 4 12 3 0 119 9 117 1 113 9 1115 10 8 6 10 5 3
12 5 4 12 3 0 119 9 117 1 113 9 1115 10 8 6 10 5 3
1330 1301 1274 1244
PCBBF137 PCBBF139 DM96VE0603AN - CONTINUOUS FAN
DIP Sw itches
DIP Sw itches
S1-1 S1-2 S1-3
Static
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Tstat Call CFM CFM CFM CFM CFM CFM CFM CFM
OFF OFF ON
G
1056 1026 991 961 929 894 864 829
OFF ON OFF
ON OFF OFF
G
13 3 0 13 0 1 12 7 4 12 4 4 122 7 119 1 116 3 113 2
ON ON OFF
G
697 654 600 557 508 460 419 371
1115 10 8 6 10 5 3
OFF ON ON
G
12 5 4 12 3 0 119 9 117 1 113 9 1115 10 8 6 10 5 3
ON OFF ON
G
12 5 4 12 3 0 119 9 117 1 113 9 1115 10 8 6 10 5 3
G
880 838 794 763 722 689 644 606
ON ON ON
G
12 5 4 12 3 0 119 9 117 1 113 9 1115 10 8 6 10 5 3
ALL POSITIONS NA
G
12 5 4 12 3 0 119 9 117 1 113 9 1115 10 8 6 10 5 3
NA
**OFF OFF OFF
G
12 5 4 12 3 0 119 9 117 1 113 9
PCBBF137 PCBBF139
CFM Rise CFM
1254 42 1171
1330 39 1244
697 N/A 557
1330 39 1244
697 N/A 557
880 N/A 763
880 N/A 763
1056 49 961
CFM CFM CFM
1053
W2
1301 39 1274 41 42 1227 42 1191 1163 1132
DM96VE0603AN - HEATING
DIP Switches
S3-1 S3-2
DIP Switches
S1-4 S2-1
Static
0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
Tstat Call CFM Rise CFM Rise Rise CFM Rise
606
ON OFF ON OFF
W1
654 N/A 600 N/A N/A 508 N/A 460 419 371
W2
1301 39 1274 41 42 1227 42 1191 1163 1132
606
W2
1026 51 997 52 54 929 56 894 864 829
ON ON ON ON
W1
654 N/A 600 N/A N/A 508 N/A 460 419 371
W2
838 N/A 794 N/A N/A 722
OFF ON OFF ON
W1
838 N/A 794 N/A N/A 722 N/A 689 644
N/A 689 644
**OFF OFF **OFF OFF
W1
12 3 0 4 2 119 9 4 3 4 4 113 9 4 6 1115 10 8 6
*NOT RECOMMENDED
**Factory Default
SINGLE STAGE COOLING^