Installation manual
Daikin Altherma 3 M
English
Installation manual
Daikin Altherma 3 M
EBLA04E2V3
EBLA06E2V3
EBLA08E2V3
EBLA04E23V3
EBLA06E23V3
EBLA08E23V3
EDLA04E2V3
EDLA06E2V3
EDLA08E2V3
EDLA04E23V3
EDLA06E23V3
EDLA08E23V3
https://daikintechnicaldatahub.eu

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin EDLA04-08EV3 and is the answer not in the manual?

Daikin EDLA04-08EV3 Specifications

General IconGeneral
ModelEDLA04-08EV3
CategoryAir Conditioner
ManufacturerDaikin
TypeSplit System
Power Supply220-240V, 50Hz
RefrigerantR32
Airflow (High)10.2 m³/min
Indoor Unit Dimensions (W x H x D)N/A (This is a chiller, not a split system)
Weight (Indoor Unit)N/A (This is a chiller, not a split system)
Noise Level (Indoor)N/A (This is a chiller, not a split system)

Summary

Specific installer safety instructions

Unit installation

Mounting the outdoor unit

Instructions for mounting the outdoor unit, covering different installation structures and securing methods.

Installing the outdoor unit

Step-by-step guide for physically installing the outdoor unit, including handling and positioning.

Piping installation

Connecting water piping

Instructions for connecting water piping, emphasizing proper valve usage and avoiding excessive force.

Protecting water circuit against freezing

Methods to protect the water circuit from freezing, including adding glycol or using freeze protection valves.

Electrical installation

Outdoor unit connections

Overview of various electrical connection points on the outdoor unit, referencing specific sections for details.

Main power supply connection

Two methods for connecting the main power supply to the unit, covering normal and preferential rates.

Backup heater power supply connection

Steps for connecting the power supply to the integrated backup heater, including safety warnings.

External backup heater kit installation

Information on installing an external backup heater kit, including bypass valve requirements.

Backup heater kit power supply connection

Detailed steps for connecting the power supply to the backup heater kit, ensuring proper grounding and capacity matching.

Connecting backup heater kit to outdoor unit

Wiring instructions to connect the external backup heater kit to the outdoor unit, covering LV and HV cables.

Connecting the user interface

Covers connecting the user interface cable to the outdoor unit and installing the interface itself.

Installing the user interface

Detailed steps for mounting the user interface and connecting its cable, including choosing wiring intakes.

Finishing the outdoor unit installation

Checking compressor insulation resistance

Procedure to measure insulation resistance of the compressor after installation to ensure it is within acceptable limits.

Configuration

Configuration wizard: Backup heater

Configuration settings for the backup heater, including type, voltage, capacity steps, and relays.

Configuration wizard: Main zone

Setting up the main leaving water zone, including emitter type and its effect on setpoint ranges.

Configuration wizard: Additional zone

Configuration settings for an additional leaving water zone, including emitter type and control methods.

Configuration wizard: Tank

Configuration options for domestic hot water tank heat-up modes and settings.

Weather-dependent curve setup

Explanation of weather-dependent operation and how curves adjust settings based on outdoor temperature.

Using weather-dependent curves

Comprehensive guide on configuring weather-dependent curves for different zones and tanks.

Commissioning

Checklist before commissioning

A pre-commissioning checklist to ensure all installation steps are completed correctly.

Checklist during commissioning

A checklist for tasks to be performed during the commissioning phase of the unit.

Checking minimum flow rate

Procedure to verify the minimum required flow rate for the system, crucial for proper operation.

Performing air purge

Steps to perform an air purge on the system to remove air from the water circuit.

Performing operation test run

Guide to running operational test cycles for heating, cooling, or DHW to verify system functionality.

Performing actuator test run

Procedure to test individual actuators like pumps and valves to confirm their operation.

Technical data

Electrical connection diagram

A comprehensive diagram showing all electrical connections for the outdoor unit and its optional parts.

Related product manuals