Instructions for mounting the outdoor unit, covering different installation structures and securing methods.
Step-by-step guide for physically installing the outdoor unit, including handling and positioning.
Instructions for connecting water piping, emphasizing proper valve usage and avoiding excessive force.
Methods to protect the water circuit from freezing, including adding glycol or using freeze protection valves.
Overview of various electrical connection points on the outdoor unit, referencing specific sections for details.
Two methods for connecting the main power supply to the unit, covering normal and preferential rates.
Steps for connecting the power supply to the integrated backup heater, including safety warnings.
Information on installing an external backup heater kit, including bypass valve requirements.
Detailed steps for connecting the power supply to the backup heater kit, ensuring proper grounding and capacity matching.
Wiring instructions to connect the external backup heater kit to the outdoor unit, covering LV and HV cables.
Covers connecting the user interface cable to the outdoor unit and installing the interface itself.
Detailed steps for mounting the user interface and connecting its cable, including choosing wiring intakes.
Procedure to measure insulation resistance of the compressor after installation to ensure it is within acceptable limits.
Configuration settings for the backup heater, including type, voltage, capacity steps, and relays.
Setting up the main leaving water zone, including emitter type and its effect on setpoint ranges.
Configuration settings for an additional leaving water zone, including emitter type and control methods.
Configuration options for domestic hot water tank heat-up modes and settings.
Explanation of weather-dependent operation and how curves adjust settings based on outdoor temperature.
Comprehensive guide on configuring weather-dependent curves for different zones and tanks.
A pre-commissioning checklist to ensure all installation steps are completed correctly.
A checklist for tasks to be performed during the commissioning phase of the unit.
Procedure to verify the minimum required flow rate for the system, crucial for proper operation.
Steps to perform an air purge on the system to remove air from the water circuit.
Guide to running operational test cycles for heating, cooling, or DHW to verify system functionality.
Procedure to test individual actuators like pumps and valves to confirm their operation.
A comprehensive diagram showing all electrical connections for the outdoor unit and its optional parts.