3 | About the system
User reference guide
9
EHBH/X04+08EA/EJ6V+9W + EHVH/X04+08S(U)18+23EA/EJ3V+6V+9W
Daikin Altherma 3 R F+W
4P629087-1 – 2020.08
3 About the system
Depending on the system layout, the system can:
Heat up a space
Cool down a space (if a heating/cooling heatpump model is installed)
Produce domestic hot water (if a DHWtank is installed)
3.1 Components in a typical system layout
d
a
b
c
e
f
g
BC
A
A Main zone. Example: Living room.
B Additional zone. Example: Bedroom.
C Technical room. Example: Garage.
a Outdoor unit heatpump
b Indoor unit heatpump
c Domestic hot water (DHW) tank
d User interface of the indoor unit
e User interface used as room thermostat
f Underfloor heating
g Radiators, heatpump convectors, or fancoil units
INFORMATION
The indoor unit and the domestic hot water tank (if installed) can be separated or
integrated depending on the indoor unit type.