INSTALLATION AND
OPERATION MANUAL
EUWAC5FZW1
EUWAC8FZW1
EUWAC10FZW1
Packaged air-cooled water chillers

Questions and Answers

  • M
    Mark MorseAug 4, 2025
    What to do if the temperature setting is not correct on my Daikin EUWAC10FZW1 Chiller?
    • W
      williamsgarrettAug 4, 2025
      If the temperature setting is incorrect on your Daikin Chiller, check the controller setpoint to ensure it is properly configured.
  • M
    Matthew HowellAug 8, 2025
    What to do if my Daikin EUWAC10FZW1 Chiller has a power supply failure?
    • K
      Kristin HarrisAug 9, 2025
      If your Daikin Chiller is experiencing a power supply failure, check the voltage on the supply panel.
  • N
    nancyduranAug 13, 2025
    What to do if my Daikin EUWAC10FZW1 Chiller has blown fuse or interrupted protection device?
    • P
      Phillip CherryAug 13, 2025
      If your Daikin Chiller has a blown fuse or an interrupted protection device, inspect the fuses and protection devices. Replace them with fuses of the same size and type, referring to the wiring diagram delivered with the unit.
  • N
    nicholsjenniferAug 17, 2025
    What to do if there are loose connections in my Daikin EUWAC10FZW1 Chiller?
    • C
      Christopher ButlerAug 17, 2025
      If you suspect loose connections in your Daikin Chiller, inspect the connections of the field wiring and the internal wiring of the unit. Tighten all loose connections.
  • E
    Emily KruegerAug 21, 2025
    What to do if the remote ON/OFF input is enabled and the remote switch is off on my Daikin EUWAC10FZW1?
    • B
      barbara87Aug 21, 2025
      If the remote ON/OFF input is enabled and the remote switch is off on your Daikin Chiller, put the remote switch on or disable the remote ON/OFF input.
  • S
    stanleysonyaAug 26, 2025
    What to do if my Daikin EUWAC10FZW1 has shorted or broken wires?
    • J
      Jeffrey HunterAug 27, 2025
      If you suspect shorted or broken wires in your Daikin Chiller, test the circuits using a tester and repair if necessary.
  • H
    Heather MooreAug 30, 2025
    What to do if the keyboard is locked on my Daikin Chiller?
    • M
      Michael SanchezAug 30, 2025
      If the keyboard is locked on your Daikin Chiller and the user parameter h9 is set to 0, unlock the controller keyboard.

Summary

Installation and Operation Manual

Installing the Unit

Technical specifications

Details of the unit's technical specifications and electrical requirements.

Selection of location

Provides criteria for selecting an appropriate installation site for the EUWAC unit.

Checking the water circuit

Procedures for inspecting the water circuit before connecting the EUWAC unit.

Connecting the water circuit

Steps for properly connecting the water inlet and outlet of the EUWAC unit.

Water charge, flow and quality

Requirements for water volume, flow rate, and quality for optimal EUWAC operation.

Field wiring

Instructions for field wiring installations, compliant with regulations.

Connection of the packaged air-cooled water chiller power supply

Guide for connecting the main power supply to the EUWAC unit.

Selection of Location

Inspecting and handling the unit

Guidelines for checking and safely handling the EUWAC unit during installation.

Unpacking and placing the unit

Instructions on how to unpack and position the EUWAC unit correctly.

Before Operation

Checks before initial start-up

Checklist of essential checks before powering on the EUWAC unit for the first time.

Power supply connection and crankcase heating

Instructions for connecting power and activating the crankcase heater.

Operation

Safety devices

Digital controller

Switching the EUWAC unit on

Step-by-step instructions for powering on the EUWAC unit.

Switching the EUWAC unit off

Instructions on how to safely switch off the EUWAC unit.

Troubleshooting

Symptom 1: The unit does not start, but the comp LED lights up

Diagnosis and correction for units failing to start with the compressor LED illuminated.

Symptom 2: The unit does not start, but the comp LED is flashing

Diagnosis and correction for units failing to start with a flashing compressor LED.

Symptom 3: The unit does not start and the comp LED does not light up

Diagnosis and correction for units failing to start with no compressor LED indication.

Symptom 4: One of the following safety devices is activated

Troubleshooting guide for activated safety devices like overcurrent relay or pressure switches.

Symptom 5: Unit stops soon after operation

Diagnosis and correction for units that stop shortly after starting operation.

Maintenance

Daikin EUWAC10FZW1 Specifications

General IconGeneral
BrandDaikin
ModelEUWAC10FZW1
CategoryChiller
LanguageEnglish