Daikin EWWQ049KAW1M - Page 124

Daikin EWWQ049KAW1M
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
∂Á¯ÂÈÚ›‰ÈÔ ÏÂÈÙÔ˘ÚÁ›·˜
10
EWWQ049~064KAW1M + ECB2+3MUBW
™˘ÁÎÚÔÙ‹Ì·Ù· ˘‰Úfi„˘ÎÙˆÓ „˘ÎÙÒÓ ÓÂÚÔ‡
D-EOMHP01008-17EU
∫‡ÚÈÔ ÌÂÓÔ‡
ªÂÙ·ÎÈÓËı›Ù ̤۷ ÛÙÔ Î‡ÚÈÔ ÌÂÓÔ‡ ¯ÚËÛÈÌÔÔÈÒÓÙ·˜ Ù·
Ï‹ÎÙÚ· g Î·È h ÁÈ· Ó· ʤÚÂÙ ÙÔ Û‡Ì‚ÔÏÔ > ÌÚÔÛÙ¿ ·fi ÙÔ
ÌÂÓÔ‡ Ù˘ ÂÈÏÔÁ‹˜ Û·˜. ¶È¤ÛÙ ÙÔ Ï‹ÎÙÚÔ q ÁÈ· Ó· ÂÈÛ¤ÏıÂÙÂ
ÛÙÔ ÂÈÏÂÁ̤ÓÔ ÌÂÓÔ‡.
ªÂÓÔ‡ ÌÂÙÚ‹ÛÂȘ
ªÂÓÔ‡ ÛËÌ›· Ú‡ıÌÈÛ˘
∞Ó¿ÏÔÁ· Ì ÙȘ Ú˘ıÌ›ÛÂȘ ÛÙÔ ÌÂÓÔ‡ Ú˘ıÌ›ÛÂˆÓ ÙÔ˘ ¯Ú‹ÛÙË Î·È
ÙÔÓ ÙÚfiÔ ÏÂÈÙÔ˘ÚÁ›·˜ „‡Í˘/ı¤ÚÌ·ÓÛ˘ Ô˘ ÂÈϤͷÙÂ,
ÌÔÚ›Ù ӷ Ì›Ù ÛÙÔ ÌÂÓÔ‡ "ÛËÌ›· Ú‡ıÌÈÛ˘" ›Ù ηÙ¢ı›·Ó
›Ù ̤ۈ ÙÔ˘ Û˘ÓıËÌ·ÙÈÎÔ‡ ÙÔ˘ ¯Ú‹ÛÙË.
ªÂÓÔ‡ Ú˘ıÌ›ÛÂȘ ¯Ú‹ÛÙË
∆Ô ÌÂÓÔ‡ "Ú˘ıÌ›ÛÂȘ ¯Ú‹ÛÙË", Ô˘ ÚÔÛٷهÂÙ·È Ì¤Ûˆ ÙÔ˘
Έ‰ÈÎÔ‡ ÚfiÛ‚·Û˘ ÙÔ˘ ¯Ú‹ÛÙË ÂÈÙÚ¤ÂÈ Ì›· Ï‹ÚË
‰È·ÌfiÚʈÛË ·Ó¿ÏÔÁ· Ì ÙȘ ÚÔÙÈÌ‹ÛÂȘ Ù˘ ÌÔÓ¿‰·˜.
ªÂÓÔ‡ ¯ÚÔÓԉȷÎfiÙ˜
°È· Ó· ¿ÚÂÙ Ú·ÁÌ·ÙÈΤ˜
ÏËÚÔÊÔڛ˜ ÏÂÈÙÔ˘ÚÁ›·˜ Û¯ÂÙÈο
Ì ÙÔÓ ÙÚfiÔ ÏÂÈÙÔ˘ÚÁ›·˜
ÂϤÁ¯Ô˘, ÙË ıÂÚÌÔÎÚ·Û›· ÙÔ˘
ÂÈÛÂÚ¯fiÌÂÓÔ˘ ÓÂÚÔ‡ ÛÙÔÓ
ÂÍ·ÙÌÈÛÙ‹ Î·È ÙÔ Û˘Ì˘ÎÓˆÙ‹
ηıÒ˜ Î·È ÙÔ ‚‹Ì· ÙÔ˘
ıÂÚÌÔÛÙ¿ÙË.
°È· Ó· ¿ÚÂÙ ÏËÚÔÊÔڛ˜
Û¯ÂÙÈο Ì ÙË ıÂÚÌÔÎÚ·Û›· ÙÔ˘
ÂÍÂÚ¯fiÌÂÓÔ˘ ÓÂÚÔ‡ ·fi ÙȘ
˘ÔÌÔÓ¿‰Â˜ 1, 2 Î·È 3 (ÌfiÓÔ ÁÈ·
Ù· 147~192).
°È· Ó· ¿ÚÂÙ ÏËÚÔÊÔڛ˜
Û¯ÂÙÈο Ì ÙËÓ Î·Ù¿ÛÙ·ÛË ÙÔ˘
Û˘ÌÈÂÛÙ‹ (ÚÒÙË ÔıfiÓË).
°È· Ó· ¿ÚÂÙ ÏËÚÔÊÔڛ˜
Û¯ÂÙÈο Ì ÙËÓ Î·Ù¿ÛÙ·ÛË ÙÔ˘
Û˘ÌÈÂÛÙ‹ (‰Â‡ÙÂÚË ÔıfiÓË).
¡· Ï¿‚ÂÙ ˘fi„Ë Û·˜ Ú·ÁÌ·ÙÈΤ˜
ÏÂÈÙÔ˘ÚÁÈΤ˜ ÏËÚÔÊÔڛ˜ Û¯ÂÙÈο
ÌÂ ÙÔ Û‡ÓÔÏÔ ÙˆÓ ˆÚÒÓ
ÏÂÈÙÔ˘ÚÁ›·˜ ÙˆÓ Û˘ÌÈÂÛÙÒÓ.
°È· Ó· ÚÔÛ‰ÈÔÚ›ÛÂÙ ٷ ÛËÌ›·
Ú‡ıÌÈÛ˘ Ù˘ ıÂÚÌÔÎÚ·Û›·˜.
°È· Ó· ÔÚ›ÛÂÙ ÙȘ ¯ÂÈÚÔΛÓËÙ˜
Ú˘ıÌ›ÛÂȘ Î·È Ó· ÂÈϤÍÂÙ ÙÔÓ
ÙÚfiÔ ÏÂÈÙÔ˘ÚÁ›·˜ ÂϤÁ¯Ô˘.
°È· Ó· ÚÔÛ‰ÈÔÚ›ÛÂÙ ÙȘ Ú˘ıÌ›ÛÂȘ
ÙÔ˘ ıÂÚÌÔÛÙ¿ÙË.
>READOUT MENU
SETPOINTS MENU
USERSETTINGS MENU
TIMERS MENU
HISTORY MENU
INFO MENU
I/O STATUS MENU
USERPASSWORD MENU
COOL/HEAT MENU
BX MANUAL MODE
INL WATER E: 12.0°C
INL WATER C: 30.0°C
THERMOSTAT STEP :2/6
BC EVAPORATOR
M1 : OUTLWATER: 07.0°C
M2: OUTLWATER: 07.0°C
M3: OUTLWATER:-03.0°C
BC COMPRESSOR STATUS
C11 : OFF-CAN STARTUP
C12: OFF-CAN STARTUP
C21: OFF-CAN STARTUP
BC COMPRESSOR STATUS
C22: OFF-CAN STARTUP
C31 : OFF- SAFETY ACT.
C32: OFF- LIMIT
BW RUNNING HOURS
C11 : 00010h 12 ; 00010h
C21 : 00010h 22 ; 00010h
C31 : 00010h 32 ; 00010h
B>INLSETP1 E : 12.0°C
INLSETP2 E : 12.0°C
INLSETP1 C : 30.0°C
INLSETP2 C : 30.0°C
BC CONTROL SETTINGS
MODE :MANUAL CONTROL
C11 : OFF 12 ; OFF
C21 : OFF 22 ; OFF
BC THERMOST.SETTINGS
STEPS : 6 STPL.: 1.5°C
STEPDIFFERENCE: 0.5°C
LOADUP: 180s-DWN: 30s
°È· Ó· ÚÔÛ‰ÈÔÚ›ÛÂÙ ÙÔÓ ÙÚfiÔ
ÏÂÈÙÔ˘ÚÁ›·˜ ÚÔÔÚ›·˜-
ηı˘ÛÙ¤ÚËÛ˘ ÙˆÓ ˘ÔÌÔÓ¿‰ˆÓ.
°È· Ó· ÚÔÛ‰ÈÔÚ›ÛÂÙ ÙÔ fiÚÈÔ Ù˘
·fi‰ÔÛ˘ (ÚÒÙË ÔıfiÓË).
°È· Ó· ÚÔÛ‰ÈÔÚ›ÛÂÙ ÙÔ fiÚÈÔ Ù˘
·fi‰ÔÛ˘ (‰Â‡ÙÂÚË ÔıfiÓË).
°È· ÚÔÛ‰ÈÔÚÈÛÌfi ÙˆÓ Ú˘ı̛ۈÓ
ÂϤÁ¯Ô˘ Ù˘ ·ÓÙÏ›·˜.
°È· Ó· ÚÔÛ‰ÈÔÚ›ÛÂÙ ÙÔ
¯ÚÔÓԉȷÎfiÙË ÚÔÁÚ·ÌÌ·ÙÈÛÌÔ‡.
°È· Ó· ÔÚ›ÛÂÙ ÙȘ ·Ú·Ì¤ÙÚÔ˘˜
Ù˘ ‰ÈÏ‹˜ ·ÓÙÏ›·˜ ÙÔ˘ ÂÍ·ÙÌÈÛÙ‹.
°È· Ó· ÔÚ›ÛÂÙ ÙȘ Ú˘ıÌ›ÛÂȘ Ù˘
ÔıfiÓ˘ ÂӉ›ÍˆÓ.
°È· Ó· ÚÔÛ‰ÈÔÚ›ÛÂÙ ·Ó
¯ÚÂÈ¿˙ÂÙ·È Îˆ‰ÈÎfi˜ ÚfiÛ‚·Û˘ ÁÈ·
Ó· Ì›Ù ÛÙ· ÌÂÓÔ‡ ÙˆÓ ÛËÌ›ˆÓ
Ú‡ıÌÈÛ˘.
°È· Ó· ÂÈÛ¤ÏıÂÙ ÛÙÔ ÌÂÓÔ‡
ۤڂȘ. (∏ ÚfiÛ‚·ÛË ÛÙÔ ÌÂÓÔ‡
·˘Ùfi ÂÈÙÚ¤ÂÙ·È ÌfiÓÔ Û ÂȉÈÎÔ‡˜
Ù¯ӛÙ˜.)
°È· Ó· ÂϤÁÍÂÙ ÙËÓ Ú·ÁÌ·ÙÈ΋
ÙÈÌ‹ ÙˆÓ ÁÂÓÈÎÒÓ ¯ÚÔÓԉȷÎÔÙÒÓ
ÙÔ˘ ÏÔÁÈÛÌÈÎÔ‡ (ÚÒÙË ÔıfiÓË).
°È· Ó· ÂϤÁ¯ÂÙ ÙËÓ Ú·ÁÌ·ÙÈ΋
ÙÈÌ‹ ÙˆÓ ÁÂÓÈÎÒÓ ¯ÚÔÓԉȷÎÔÙÒÓ
ÙÔ˘ ÏÔÁÈÛÌÈÎÔ‡ (‰Â‡ÙÂÚË ÔıfiÓË).
°È· Ó· ÂϤÁÍÂÙ ÙËÓ Ú·ÁÌ·ÙÈ΋
ÙÈÌ‹ ÙˆÓ ¯ÚÔÓԉȷÎÔÙÒÓ ÙÔ˘
Û˘ÌÈÂÛÙ‹ (ÚÒÙË ÔıfiÓË).
°È· Ó· ÂϤÁÍÂÙ ÙËÓ Ú·ÁÌ·ÙÈ΋
ÙÈÌ‹ ÙˆÓ ¯ÚÔÓԉȷÎÔÙÒÓ ÙÔ˘
Û˘ÌÈÂÛÙ‹ (‰Â‡ÙÂÚË ÔıfiÓË).
C LEAD-LAG SETTINGS
LEAD-LAG MODE : AUTO
LEAD-LAG HOURS: 1000h
BC CAP. LIM. SETTINGS
MODE : REMOTE DIG INP.
L1M1 : OFF 2: OFF 3: OFF
L2M1 : OFF 2: OFF 3: OFF
BC CAP. LIM. SETTINGS
L3M1 : OFF 2: OFF 3: OFF
L4M1 : OFF 2: OFF 3: OFF
BC PUMPCONTROL
PUMPLEADTIME : 020s
PUMPLAGTIME : 000s
DAILY ON : Y AT : 00h00
BC SCHEDULE TIMER
ENABLE TIMER : N
ENABLE HOLIDAY PER : N
BC HOLIDAY : 01 TO 03
1 : 00h00 -
2: 00h00 -
3: 00h00 -
BC DUAL EVAP. PUMP
MODE : AUTOM. ROTATION
OFFSET ON RH : 0048h
BC DISPLAY SETTINGS
LANGUAGE : ENGLISH
TIME : 00h00
DATE : 00/01/2001
BC SETPOINT PASSWORD
PASSWORD NEEDED TO
CHANGE SETPOINTS : Y
BC ENTER SERVICE
PASSWORD : 0000
BX GENERAL TIMERS
LOADUP : 000s - DWN : 000s
PUMPLEAD : 000s
FLOWSTOP : 00s
BC COMPRESSOR TIMERS
COMPR. STARTED : 00s
BC COMPRESSOR TIMERS
C11 GRD : 000s AR : 000s
C12 GRD : 000s AR : 000s
C21 GRD : 000s AR : 000s
BW COMPRESSOR TIMERS
C22 GRD : 000s AR : 000s
C31 GRD : 000s AR : 000s
C32 GRD : 000s AR : 000s