14
Useful Functions Useful Functions
INTELLIGENT EYE operation is useful for energy saving
People are detected in the sensing area.
No people are detected in the sensing area.
The air conditioner is in normal operation while the
sensor is detecting human movement.
The air conditioner will switch to energy-saving mode after
20 minutes.
Energy saving operation
• Ifnopresencedetectedintheroomfor20minutes,theenergysavingoperationwillstart,andtheINTELLIGENTEYElampgoesoff.
If human movement is detected again, the INTELLIGENT EYE lamp lights up and energy saving operation terminates.
• This operation changes the temperature by +2°C in COOL / +2°C in DRY operation from the set temperature.
When the room temperature exceeds 30°C, the operation changes the temperature by +1°C in COOL / +1°C in DRY operation from the
set temperature.
• ThisoperationdecreasestheairowrateslightlyinFANoperationonly.
NOTE
Note on COMFORT AIRFLOW operation
• TheairowratewillbesettoAUTO.Iftheupanddownairowdirectionisselected,COMFORTAIRFLOWoperationwillbecancelled.
Notes on INTELLIGENT EYE operation
• Application range is as follows.
90°
55°
7m
55°
Vertical angle 90°
(Side view)
Horizontal
angle 110°
(Top view)
7m
• The sensor may not detect moving objects further than 7m away. (Please see the application range)
• Sensor detection sensitivity changes according to the indoor unit location, the speed of passers-by, temperature range, etc.
• Thesensorcouldalsomistakenlydetectpets,sunlight,utteringcurtainsandlightreectedoffofmirrorsaspassers-by.
• NIGHT SET mode
Page 18
will not switch on during use of INTELLIGENT EYE operation.
Note on combination of COMFORT AIRFLOW operation and INTELLIGENT EYE operation
• TheairowratewillbesettoAUTO.Iftheupanddownairowdirectionisselected,COMFORTAIRFLOWoperationwillbecancelled.
Priority is given to the function of whichever button is pressed last.
COMFORT AIRFLOW /
INTELLIGENT EYE Operation
01_EN_3P642602-1E.indd 14 25-Feb-21 11:19:16 AM