Do you have a question about the Daikin FAY71LVE and is the answer not in the manual?
Cooling Capacity | 7.1 kW |
---|---|
Heating Capacity | 8.0 kW |
Energy Efficiency Ratio (EER) | 3.21 |
Refrigerant | R32 |
Type | Split System |
Seasonal Energy Efficiency Ratio (SEER) | 6.10 |
Outdoor Unit Noise Level | 49 dBA |
Power Supply | 220-240V/50Hz |
List of applicable outdoor and indoor units for the R-FU Series.
List of applicable outdoor and indoor units for the R-KU Series.
List of applicable outdoor and indoor units for the R-NU Series.
List of applicable outdoor and indoor units for the RZQ-B Series.
List of applicable outdoor and indoor units for the RZR-HU Series.
Provides an overview of troubleshooting symptoms and corresponding measures.
Troubleshooting guide for when the equipment fails to operate.
Troubleshooting steps for intermittent operation issues.
Troubleshooting steps when cooling performance is insufficient.
Troubleshooting for issues related to white mist discharge.
Explains how to use the remote controller for self-diagnosis.
Details self-diagnosis procedures for wired controllers BRC1C61/BRC1D61.
Details self-diagnosis procedures for wired controller BRC1E61.
Lists and describes various error codes for indoor and outdoor units.
Details error codes specific to indoor units.
Details error codes specific to outdoor units and system series.
Troubleshooting steps for A0 error related to external protection devices.
Troubleshooting guide for A1 error indicating indoor unit PCB abnormality.
Troubleshooting for A6 error related to indoor unit fan motor issues.
Troubleshooting steps for A9 error concerning the EEV coil.
Troubleshooting C1 error related to transmission between PCBs.
Troubleshooting guide for E0 error related to safety device activation.
Troubleshooting steps for E1 error indicating outdoor unit PCB issues.
Troubleshooting guide for E3 error related to high pressure system.
Troubleshooting steps for E4 error related to low pressure system.
Troubleshooting guide for E5 error related to compressor motor lock.
Troubleshooting steps for E6 error related to compressor overcurrent.
Troubleshooting for E7 error related to outdoor unit fan motor issues.
Troubleshooting steps for E9 error related to electronic expansion valve.
Troubleshooting for F3 error related to discharge pipe temperature.
Troubleshooting guide for F6 error indicating refrigerant overcharge.
Troubleshooting steps for H3 error related to high pressure switch.
Troubleshooting for H4 error related to low pressure sensor system.
Troubleshooting for various thermistor system abnormalities.
Troubleshooting steps for J1 error related to pressure sensor.
Troubleshooting for J5 error related to suction pipe thermistor.
Troubleshooting guide for L1 error indicating outdoor unit PCB abnormality.
Troubleshooting steps for L4 error related to DC output overcurrent.
Troubleshooting for L5 error related to inverter compressor overcurrent.
Troubleshooting for L8 error related to electronic thermal switch.
Troubleshooting steps for L8 error related to inverter current.
Troubleshooting for L9 error related to stall prevention.
Troubleshooting steps for L9 error related to inverter startup.
Troubleshooting for LC error between inverter and control PCB.
Troubleshooting steps for P1 error related to inverter over-ripple protection.
Troubleshooting for P1 error related to power supply issues.
Troubleshooting for P4 error related to radiation fin thermistor.
Troubleshooting steps for PJ error related to capacity setting.
Troubleshooting guide for U0 error related to refrigerant shortage.
Troubleshooting steps for U1 error related to reverse phase.
Troubleshooting for U2 error related to insufficient voltage.
Troubleshooting steps when check operation is not executed.
Troubleshooting U4/UF error for transmission between indoor/outdoor units.
Troubleshooting for U5 error between indoor unit and remote controller.
Troubleshooting for U8 error between main and sub remote controllers.
Troubleshooting U9 error for transmission between units in the same system.
Troubleshooting steps for UA error related to field setting switch.
Troubleshooting UA error for incorrect unit combinations.
Troubleshooting for UA error related to field setting switch.
Troubleshooting steps for UC error related to centralized address settings.
Troubleshooting for UE error between centralized controller and indoor unit.
Troubleshooting steps for UF error related to field wiring mis-connection.
Troubleshooting for UF error when the system is not set.
Troubleshooting UF error for transmission, piping, or refrigerant issues.
Troubleshooting for UF error related to transmission system abnormality.
Troubleshooting UH error for system/refrigerant address issues.