SPLIT SYSTEM Air Conditioner
OPERATION MANUAL
MODELS
(Wall mounted type)
FAQ71CVEB FAQ100CVEB
English
Deutsch
Français
Español
Italiano
Nederlands
Portugues
3P184442-10J.book Page 1 Thursday, October 27, 2011 6:17 PM

Other manuals for Daikin FAQ71CVEB

Questions and Answers

  • W
    Wesley MillerAug 12, 2025
    Why is my Daikin Air Conditioner not cooling or heating sufficiently?
    • A
      Anthony SmithAug 12, 2025
      If your Daikin Air Conditioner isn't cooling or heating enough, several factors could be at play. First, check for any obstructions blocking the air inlet or outlet of either the indoor or outdoor unit and ensure proper ventilation by removing any obstacles. Also, check if the air filter is clogged. Make sure the set temperature is appropriate for your needs. Verify that the FAN SPEED isn't set to LOW. Adjust the airflow angle for better circulation. Ensure all doors and windows are closed tightly. Reduce direct sunlight entering the room during cooling. Consider if there are too many people in the room during cooling, or if there's an excessive heat source.
  • E
    ekellerAug 16, 2025
    Why does my Daikin Air Conditioner stop operating after starting?
    • R
      Richard FowlerAug 16, 2025
      If your Daikin Air Conditioner stops soon after you turn it on, check to see if the air inlet or outlet of either the outdoor or indoor unit is blocked by obstacles. Additionally, inspect the air filter to ensure it is not clogged.
  • W
    wardteresaAug 20, 2025
    Why did my Daikin Air Conditioner start or stop on its own?
    • J
      Jose DavidAug 20, 2025
      If your Daikin Air Conditioner turns on or off without you pressing the power button, verify that the ON/OFF timer operation isn't active. Also, check to make sure that a remote control device is not connected. Finally, check the display for centralized control to see if it is lit.
  • J
    Jessica GarnerAug 25, 2025
    What to do if Daikin FAQ71CVEB detects multiple master units?
    • A
      Andrew MillerAug 25, 2025
      If your Daikin Air Conditioner detects multiple master units, connect the remote controller to only one indoor unit.
  • A
    Allison MooreAug 28, 2025
    What to do if Daikin FAQ71CVEB has gas shortage due to clogging in refrigerant piping?
    • L
      Leonard GeorgeAug 28, 2025
      If you suspect clogging in the refrigerant piping system of your Daikin Air Conditioner, check for a failure to open the stop valve and any clogging within the refrigerant system.
  • L
    Loretta WilliamsAug 31, 2025
    What does excess indoor units connected error mean on Daikin FAQ71CVEB?
    • M
      Matthew HahnAug 31, 2025
      This error will be displayed if five or more indoor units are connected to your Daikin Air Conditioner.
  • N
    Nathan ColeSep 4, 2025
    What to do if my Daikin FAQ71CVEB does not operate at all?
    • T
      Tyler BrownSep 4, 2025
      If your Daikin Air Conditioner isn't working, start by checking the fuse to see if it has blown. Next, inspect the power circuit breaker to ensure it hasn't tripped. Finally, verify that there isn't a power failure in your area.
  • L
    Laura Rodgers MDSep 8, 2025
    Why does my Daikin Heat Pump emit an odor?
    • K
      Kyle CalhounSep 8, 2025
      If your Daikin Heat Pump emits an odor, it's likely due to room smells and cigarette odors that have accumulated inside the indoor unit. To resolve this, the inside of the indoor unit must be cleaned.

Summary

GB Disposal requirements

WHAT TO DO BEFORE OPERATION

PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM

Specific precautions for group or dual remote control systems.

SAFETY PRECAUTIONS

OPERATION RANGE

INSTALLATION SITE

OPERATION PROCEDURE

OPERATION CHARACTERISTICS

CHARACTERISTICS OF THE COOLING OPERATION

Details cooling mode behavior and automatic adjustments.

CHARACTERISTICS OF THE HEATING OPERATION

Details heating mode behavior and automatic adjustments.

DEFROST OPERATION

Explains the defrost mode for the outdoor unit.

OUTSIDE AIR TEMPERATURE AND HEATING CAPACITY

Discusses heating performance based on outside temperature.

CHARACTERISTICS OF THE PROGRAM DRY OPERATION

Explains humidity control operation.

AIRFLOW DIRECTION ADJUST

How to adjust the airflow direction.

MOVEMENT OF THE AIRFLOW FLAP

How microcomputer controls airflow flap movement.

RECOMMENDED FLAP POSITIONS

Suggests optimal flap positions for cooling and heating.

OPTIMUM OPERATION

MAINTENANCE (FOR SERVICE PERSONNEL)

HOW TO CLEAN THE AIR FILTER

Step-by-step guide to cleaning the air filter.

HOW TO CLEAN AIR INLET, AIR OUTLET, EXTERIOR, AND REMOTE CONTROLLER

Instructions for cleaning external parts and remote.

HOW TO CLEAN THE FRONT PANEL

Procedure for cleaning the removable front panel.

NOT A MALFUNCTION OF THE AIR CONDITIONER

THE SYSTEM DOES NOT OPERATE

Troubleshooting steps for a system that does not start.

THE OPERATION SOMETIMES STOPS

Explains why operation might stop intermittently.

THE FAN SPEED IS DIFFERENT FROM THE SETTING

Explains variations in fan speed.

AIR BLOW DIRECTION IS NOT AS SPECIFIED

Addresses issues with airflow direction.

THE AIRFLOW DIRECTION DIFFERS FROM THE REMOTE CONTROLLER DISPLAY

Explains discrepancies between display and actual airflow.

AIRFLOW FLAPS DO NOT CLOSE

Explains why airflow flaps might not close.

WHITE MIST COMES OUT OF A UNIT

Explains the occurrence of white mist.

NOISE OF AIR CONDITIONERS

Describes normal operational noises.

DUST FROM THE UNITS

Addresses dust expelled from the unit.

THE UNITS GIVE OFF ODORS

Explains why units might emit odors.

TROUBLE SHOOTING

IF THE SYSTEM DOES NOT OPERATE AT ALL

Troubleshooting steps for a system that won't operate.

IF THE SYSTEM STOPS OPERATING AFTER OPERATION IS COMPLETE

Troubleshooting when the system stops after use.

THE SYSTEM OPERATES BUT IT DOES NOT SUFFICIENTLY COOL OR HEAT

Addresses insufficient cooling or heating performance.

THOUGH THE ON;OFF BUTTON WAS NOT PRESSED, THE UNIT STARTED OR STOPPED

Troubleshoots unexpected unit starts or stops.

Daikin FAQ71CVEB Specifications

General IconGeneral
CategoryAir Conditioner
TypeSplit System
Cooling Capacity7.1 kW
Power SourceElectric
Heating Capacity8.0 kW
RefrigerantR410A
Refrigerant Pipe ConnectionLiquid: 9.52mm, Gas: 15.9mm
Power Supply1 Phase, 220-240V, 50Hz
Operating Temperature (Cooling)18°C to 46°C
Operating Temperature (Heating)-15°C to 24°C

Related product manuals