13 English
7-2 SPECIFICATIONS FOR FIELD WIRE
The remote controller cord should be procured locally. Refer to the Table 4 when preparing one.
Ta bl e 4
NOTE
1. Shows only in case of protected pipes. Use H07RN-F in case of no protection.
2. For European and Asian market: Vinyl cord with sheath or cable (Insulated thickness: 1 mm or more)
For Australian regular: Shield wire (Insulated thickness: 1 mm or more)
Wire
Size (mm
2
)
Length
Wiring between units
H05VV-U4G
(NOTE 1)
2.5 –
Remote controller cord
Vinyl cord with sheath or cable (2 wire)
(NOTE 2)
0.75 - 1.25 Max. 500m
01_EN_3P083811-3T.fm Page 13 Friday, September 3, 2004 10:17 AM