OPERATION MANUAL
SPLIT SYSTEM Air Conditioner
English
Bahasa
Indonesia
00_CV_3P338600-20K.indd 1 8/24/2015 15:01:00

Questions and Answers

  • B
    barbarapaulAug 9, 2025
    What to do if Daikin FBQ100EVE4 Air Conditioner does not turn on?
    • C
      Charles Gonzalez VAug 9, 2025
      If your Daikin Air Conditioner isn't turning on, check the following: * See if a fuse has blown and turn off the power supply. * Check if the power circuit breaker is blown. If the tab is in the OFF position, turn it on. However, if the tab is in the trip position, do not turn it on and contact your local dealer. * Make sure direct sunlight isn't entering the room. Use curtains or blinds. * Consider if there are too many people in the room. * Assess if the heat source in the room is excessive.
  • J
    Jared HigginsAug 19, 2025
    Why Daikin Air Conditioner turns on or off by itself?
    • R
      Robert BenderAug 19, 2025
      If your Daikin Air Conditioner is turning on or off without pressing the ON/OFF button, consider these possibilities: * Check if the ON/OFF timer is active and turn it off. Consult the remote controller's manual for instructions. * Verify whether a remote control device is connected. Contact the central control room that initiated the stop. * See if the display for centralized control is lit. If so, contact the central control room that directed the stop.
  • N
    nancywheelerAug 28, 2025
    What to do if Daikin FBQ100EVE4 malfunctions?
    • T
      Thomas BuckAug 28, 2025
      If your Daikin Air Conditioner experiences any of the following malfunctions, take the indicated measures: * If a safety device (fuse, power circuit breaker, or earth leakage breaker) frequently activates, do not turn on the main power switch. * If the ON/OFF switch malfunctions, turn off the main power switch. * If water leaks from the indoor unit, stop the operation. * If the display shows “[”, “UNIT No.”, and flashes the OPERATION lamp with a “MALFUNCTION CODE” (BRC1C, BRC1D), notify your local dealer and provide the malfunction code.

Summary

Safety Precautions

WARNING Safety Classification

Defines warnings indicating a potential for death or serious injury if not avoided.

CAUTION Safety Classification

Defines cautions indicating potential minor injury or property damage.

Installation Site

Operation Characteristics

Maintenance (For Service Personnel)

Not Malfunction of the Air Conditioner

Unit Non-Response Issues

Explains reasons for the unit not starting immediately and troubleshooting steps for lack of operation.

Intermittent Operation Stops

Addresses temporary shutdowns caused by communication errors or external electrical noise.

Troubleshooting

Failure to Operate

Diagnostic steps for when the air conditioner does not operate at all, checking power supply and circuit breakers.

Post-Operation Stoppages

Troubleshooting for units stopping after operation, focusing on airflow blockages and filter cleanliness.

Insufficient Performance Diagnosis

Steps to resolve poor cooling or heating, including checking for obstructions, filter status, settings, and environmental factors.

Troubleshooting Continued

Unintended Operation Control

Investigating causes for operation starting or stopping without user input, such as timers or remote control interference.

Malfunction Code and Safety Alerts

Actions to take when safety devices trip, or specific malfunction codes and indicators appear on the unit.

Daikin FBQ100EVE4 Specifications

General IconGeneral
Energy Efficiency Class (Cooling)A
Energy Efficiency Class (Heating)A
RefrigerantR32
Power Supply220-240V / 50Hz / 1Phase
Sound Pressure Level (Indoor)22-43 dB(A)