EasyManua.ls Logo

Daikin FCN50FV1 - Page 28

Daikin FCN50FV1
51 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
Performance Data
3
rd
Step:
To obtain the TC, SC & PI for
(a) Indoor Condition: 25°C DB, 17°C WB
Outdoor Condition: 37°C DB
EWB EDB
Outdoor temperature
35°C 37°C 40°C
TC SC PI TC SC PI TC SC PI
25 17 1.87 1.63 0.63 x y z 1.74 1.52 0.68
By Interpolation Method
37°C – 35°C
=
x – 1.87kW
40°C – 35°C 1.74kW – 1.87kW
x = 1.82kW
Similarly,
y = 1.59kW
z = 0.65kW

Related product manuals