Do you have a question about the Daikin FDBG26NUV1 and is the answer not in the manual?
Details troubleshooting steps for scenarios where the equipment fails to operate.
Troubleshooting steps for issues where only the indoor fan operates, but the compressor does not.
Troubleshooting guide for units that start operation but stop shortly thereafter.
Troubleshooting for situations where the unit cannot be restarted immediately after shutdown.
Steps for diagnosing issues when the unit operates but fails to provide cooling.
Troubleshooting for units that operate but do not provide heating.
Comprehensive list of error codes, their descriptions, and applicable models.
Provides detailed explanations and diagnostic steps for specific error codes.
Troubleshooting for Error Code A0: External Protection Device actuation.
Troubleshooting for Error Code A1: Indoor Unit PCB abnormality.
Troubleshooting for Error Code A3: Drain Water Level System abnormality.
Troubleshooting for Error Code A6: Indoor Unit Fan Motor abnormality.
Troubleshooting for Error Code A6: Fan Motor lock or overload.
Troubleshooting for Error Code A8: Abnormal Power Supply Voltage.
Troubleshooting for Error Code A9: Electronic Expansion Valve Coil (Y1E) abnormality.
Troubleshooting for Error Code AF: Drain System abnormality.
Troubleshooting for Error Code AF: Drain Level above Limit.
Troubleshooting for Error Code AJ: Capacity Setting Abnormality.
Troubleshooting for Error Code C1: Transmission error between Indoor Unit PCB and Fan PCB.
Troubleshooting for Error Code C1: Transmission error between Indoor Unit PCB and Adaptor PCB.
Troubleshooting for Error Codes C4, C5, C9: Thermistor Abnormality.
Troubleshooting for Error Code C6: Defective combination between Indoor Unit PCB and Fan PCB.
Troubleshooting for Error Code E0: Actuation of Safety Device.
Troubleshooting for Error Code E0: Activation of Outdoor Unit Protection Device.
Troubleshooting for Error Code E1: Outdoor Unit PCB Abnormality.
Troubleshooting for Error Code E3: High Pressure System Abnormality.
Troubleshooting for Error Code E3: Abnormally High Pressure Level (HPS).
Troubleshooting for Error Code E3: High Pressure Abnormality (HPS).
Troubleshooting for Error Code E3: Actuation of High Pressure Switch.
Troubleshooting for Error Code E4: Low Pressure System Abnormality.
Troubleshooting for Error Code E4: Actuation of Pressure Sensor.
Troubleshooting for Error Code E4: Low Pressure Sensor System Abnormality.
Troubleshooting for Error Code E4: Low Pressure System Abnormality.
Troubleshooting for Error Code E5: Compressor Motor Lock.
Troubleshooting for Error Code E6: Compressor Overcurrent.
Troubleshooting for Error Code E7: Outdoor Unit Fan Motor Abnormality.
Troubleshooting for Error Code E9: Electronic Expansion Valve Abnormality.
Troubleshooting for Error Code E9: Electronic Expansion Valve Coil Abnormality.
| Brand | Daikin |
|---|---|
| Model | FDBG26NUV1 |
| Category | Air Conditioner |
| Language | English |