TECHNICAL MANUAL
Split Systems Air Conditioner
Ducted Blower H Series
FDN/FGN-H Series
— Cooling Only [50Hz] —
R410A
TM-5SBH-MSS-STA3
Supersede : TM-5SBH-MSS-STA2

Questions and Answers

  • A
    Alison JamesAug 14, 2025
    Why is my Daikin FDN100HV1(4) Air Conditioner airflow so weak and not cooling the room?
    • J
      justinrodriguezAug 14, 2025
      If your Daikin Air Conditioner's airflow is too slow, or the room isn't cooling enough, several factors could be at play. First, check the air filter; a dirty filter can significantly impede airflow, so clean it. Ensure that all doors and windows are closed to prevent warm air from entering the room. Also, make sure that neither the air suction nor the discharge vents of the indoor and outdoor units are blocked. Finally, verify that the temperature setting is appropriately low.
  • M
    Monica CarpenterAug 17, 2025
    Why does my Daikin Air Conditioner discharge airflow have a bad odor?
    • R
      Rebecca MooreAug 17, 2025
      If your Daikin Air Conditioner emits a bad odor, it could be due to smoke particles, perfume, or other substances that have stuck to the coil. It is recommended to contact your nearest dealer.
  • G
    Gloria CarrollAug 21, 2025
    How to restart Daikin Air Conditioner after power failure?
    • E
      Erin BurgessAug 21, 2025
      If your Daikin Air Conditioner unit doesn't turn back on after a power outage, try turning on the unit using the wireless or wired controller.
  • B
    brownsamuelAug 25, 2025
    What to do if water is flowing out from my Daikin FDN100HV1(4)?
    • L
      Lisa BurkeAug 26, 2025
      If water is flowing out of your Daikin Air Conditioner, switch off the unit and contact your nearest dealer.
  • S
    Shane JohnsonAug 28, 2025
    Why does my Daikin FDN100HV1(4) Air Conditioner compressor operate continuously?
    • M
      Megan CalhounAug 29, 2025
      If the compressor in your Daikin Air Conditioner runs non-stop, the issue might stem from a few causes. A dirty air filter can cause the compressor to work harder than necessary, so start by cleaning it. Also, check your temperature settings: if you're cooling, the temperature might be set too low; if you're heating, it might be too high. Adjust the temperature accordingly to see if that resolves the issue.
  • K
    Kristin RoseSep 2, 2025
    What to do if there is condensation on the front air grille of my Daikin Air Conditioner?
    • S
      shepardstephanieSep 2, 2025
      If you notice condensation on the front grille of your Daikin Air Conditioner's indoor unit, it's likely due to air humidity after prolonged use. To address this, try increasing the temperature setting and running the unit at a high fan speed.
  • S
    Samantha WilliamsSep 5, 2025
    What is the reason for hissing airflow sound from Daikin FDN100HV1(4) unit?
    • J
      Jacob JacobsSep 5, 2025
      If you hear a hissing sound from your Daikin Air Conditioner during operation, it is caused by liquid refrigerant flowing into the evaporator coil.
  • J
    James FlowersSep 8, 2025
    Why doesn't the compressor start immediately on my Daikin FDN100HV1(4)?
    • S
      Sara NavarroSep 9, 2025
      If your Daikin Air Conditioner doesn't start the compressor immediately after being turned on, it might be due to a built-in protection mechanism that prevents frequent starts. Wait for approximately 3 to 4 minutes, and the compressor should start automatically.

Summary

Application Information

Operating Range

Specifies allowed operating temperatures for cooling.

Installation Guideline

Provides instructions for indoor unit installation.

Refrigerant Piping

Maximum Piping Length and Bends

Details piping limits and equivalent lengths.

Selection Process

Drive Package Selection

Example of selecting a drive package for 2FGN250HY1.

Fan Performance Curve Example

Shows fan curve for 2FGN250HY1 with example selection.

Engineering & Physical Data

Unit Specifications

Provides technical specifications for indoor/outdoor units.

Performance Data

Calculation Steps

Explains how to use interpolation for performance calculations.

Wiring Diagrams

Cooling Only Wiring Diagrams

Shows wiring diagrams for cooling mode.

Service & Maintenance

Troubleshooting

Fault Conditions and Tips

Lists common faults and troubleshooting tips.