Disassembly and Maintenance ESIE05-04
5–46 Part 5 – Disassembly and Maintenance
3
1
5
5
1.12.3 Removal of Decoration Panel
Warning Be sure to wait 10 minutes or more after turning off all power supplies before disassembling work.
Procedure:
Step Procedure Points
1 Removing the decoration
panel
1 Remove the switch box
cover and disconnect the
connector of swing motor
from the harness
connector of electric
parts.
2 Check that the
provisional hanger is in
the position where it can
be engaged with the hook
of switch box.
(S2636)
(S2637
)
Provisional hanger
Hook of switch box
(S2638)