28 Specifications
50 Hz, 220 - 230 - 240 V
Model
FTXS42J2V1B FTXS50J2V1B
Cooling Heating Cooling Heating
Rated Capacity 4.2 kW Class 5.0 kW Class
Front Panel Color White White
Airflow Rate
H
m³/min
(cfm)
11.3 (399) 12.2 (431) 11.6 (410) 12.1 (427)
M 9.0 (318) 9.7 (343) 9.2 (325) 9.8 (346)
L 6.8 (240) 7.3 (258) 7.0 (247) 7.6 (268)
SL 5.9 (208) 6.4 (228) 6.0 (212) 6.7 (237)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 23 23
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A 0.11 - 0.11 - 0.11 0.14 - 0.14 - 0.13 0.12 - 0.12 - 0.11 0.15 - 0.14 - 0.14
Power Consumption (Rated) W 24 - 24 - 24 30 - 30 - 30 26 - 26 - 26 32 - 32 - 32
Power Factor (Rated) % 99.2 - 94.9 - 90.9 97.4 - 93.2 - 96.2 98.5 - 94.2 - 98.5 97.0 - 99.4 - 95.2
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) mm 295 × 800 × 215 295 × 800 × 215
Packaged Dimensions (H × W × D) mm 289 × 870 × 366 289 × 870 × 366
Weight (Mass) kg 10 10
Gross Weight (Gross Mass) kg 14 14
Sound
Pressure
Level
H / M / L / SL dB(A) 45 / 39 / 33 / 30 45 / 39 / 33 / 30 46 / 40 / 34 / 31 47 / 41 / 34 / 31
Sound Power Level dB 61 61 62 63
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping
Connection
Liquid mm
φ
6.4
φ
6.4
Gas mm
φ 9.5 φ 12.7
Drain mm
φ 18.0 φ 18.0
Drawing No. 3D070567A 3D070568A
Model
FTXS60GV1B FTXS71GV1B
Cooling Heating Cooling Heating
Rated Capacity 6.0 kW Class 7.1 kW Class
Front Panel Color White White
Airflow Rate
H
m³/min
(cfm)
16.0 (565) 17.2 (607) 17.2 (607) 19.5 (689)
M 13.5 (477) 14.9 (526) 14.5 (512) 16.7 (590)
L 11.3 (399) 12.6 (445) 11.5 (406) 14.2 (501)
SL 10.1 (357) 11.3 (399) 10.5 (371) 12.6 (445)
Fan
Type Cross Flow Fan Cross Flow Fan
Motor Output W 43 43
Speed Steps 5 Steps, Quiet, Auto 5 Steps, Quiet, Auto
Air Direction Control Right, Left, Horizontal, Downward Right, Left, Horizontal, Downward
Air Filter Removable / Washable / Mildew Proof Removable / Washable / Mildew Proof
Running Current (Rated) A 0.19 - 0.18 - 0.17 0.21 - 0.20 - 0.19 0.21 - 0.20 - 0.19 0.28 - 0.27 - 0.26
Power Consumption (Rated) W 40 - 40 - 40 45 - 45 - 45 45 - 45 - 45 60 - 60 - 60
Power Factor (Rated) % 95.7 - 96.6 - 98.0 97.4 - 97.8 - 98.7 97.4 - 97.8 - 98.7 97.4 - 96.6 - 96.2
Temperature Control Microcomputer Control Microcomputer Control
Dimensions (H × W × D) mm 290 × 1,050 × 250 290 × 1,050 × 250
Packaged Dimensions (H × W × D) mm 361 × 1,145 × 364 361 × 1,145 × 364
Weight (Mass) kg 12 12
Gross Weight (Gross Mass) kg 18 18
Sound
Pressure
Level
H / M / L / SL dB(A) 45 / 41 / 36 / 33 44 / 40 / 35 / 32 46 / 42 / 37 / 34 46 / 42 / 37 / 34
Sound Power Level dB 61 60 62 62
Heat Insulation Both Liquid and Gas Pipes Both Liquid and Gas Pipes
Piping
Connection
Liquid mm
φ
6.4
φ
6.4
Gas mm
φ 12.7 φ 15.9
Drain mm
φ 18.0 φ 18.0
Drawing No. 3D065512A 3D065513A
Conversion Formulae
kcal/h = kW × 860
Btu/h = kW × 3412
cfm = m³/min × 35.3