Indoor Unit Control (RA Models) SiBE121135
80 Function and Control
Floor Standing Type: FVXS Series
Floor / Ceiling Suspended Dual Type
3-D Airflow Wall Mounted Type: FTXS-J/G Series
Alternative repetition of vertical and horizontal swing motions enables uniform air-conditioning of
the entire room. This function is effective for starting the air conditioner.
When the horizontal swing and vertical swing are both set to automatic operation, the airflow
becomes 3-D airflow. The horizontal and vertical swing motion is altered and the airflow
direction changes in the order shown in the following diagram.
(1): The vertical blades (louvers) move from the right to the left.
(2): The horizontal blades (flaps) move downward.
(3): The vertical blades (louvers) move from the left to the right.
(4): The horizontal blades (flaps) move upward.
Vertical Swing (up and down)
Cooling / Dry Heating
Upward
airflow limit
OFF
(R6831) (R6829)
Upward
airflow limit
ON
(R6832) (R6830)
Vertical Swing (up and down)
Cooling / Dry / Fan Heating
Ceiling
(R2964)
(R2963)
Floor
(R2967)
(R2966)
25˚
90˚
40˚
90˚
20˚
90˚
90˚
20˚
40˚
20˚
95˚
65˚
40˚
20˚
95˚
65˚
(R13554)
(1)(2)
(3) (4)