Pocket
Manual
Service Diagnosis
Si20 - 701_B

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin FHYK45FJV1 and is the answer not in the manual?

Daikin FHYK45FJV1 Specifications

General IconGeneral
CategoryAir Conditioner
ModelFHYK45FJV1
Cooling Capacity4.5 kW
Heating Capacity5.0 kW
Power Supply220-240 V, 50 Hz
RefrigerantR32

Summary

Symptom-based Troubleshooting

2.2 Equipment Does Not Operate

Troubleshooting steps for when the equipment fails to operate.

2.3 Indoor Unit Fan Operates, but Compressor Does Not Operate

Diagnoses why the indoor unit fan runs but the compressor does not operate.

2.4 Cooling / Heating Operation Starts but Stops Immediately

Troubleshooting steps for cooling/heating operations that start and stop abruptly.

Troubleshooting by Remote Controller

3.1 Procedure of Self-diagnosis by Remote Controller

Details on how to perform self-diagnosis using the remote controller.

3.2 Error Codes and Description

Lists and explains various error codes for indoor and outdoor units.

3.3 Detailed Error Codes

Provides detailed explanations and diagnostic steps for specific error codes.

3.4 A0 Error of External Protection Device

Diagnoses and resolves errors related to external protection devices.

3.5 A1 Indoor Unit PCB Abnormality

Addresses issues concerning abnormalities in the indoor unit PCB.

3.6 A3 Drain Water Level System Abnormality

Diagnoses abnormalities related to the drain water level system.

3.7 A6 Indoor Unit Fan Motor Abnormality

Details troubleshooting for indoor unit fan motor abnormalities.

3.8 A6 Fan Motor (M1F) Lock, Overload

Troubleshoots fan motor lock or overload conditions.

3.9 A7 Swing Flap Motor Abnormality / Lock

Addresses swing flap motor abnormalities and lock conditions.

3.10 A8 Abnormal Power Supply Voltage

Diagnoses issues related to abnormal power supply voltage.

3.11 A9 Electronic Expansion Valve Coil (Y1E) Abnormality

Covers abnormalities in the electronic expansion valve coil.

3.12 AF Drain System Abnormality

Diagnoses abnormalities within the drain system.

3.13 AF Drain Level above Limit

Addresses issues when the drain level exceeds the limit.

3.14 AJ Capacity Setting Abnormality

Resolves issues related to incorrect capacity settings.

3.15 C1 Transmission Error (between Indoor Unit PCB and Fan PCB)

Resolves transmission errors between indoor PCB and fan PCB.

3.16 C1 Transmission Error (between Indoor Unit PCB and Adaptor PCB)

Addresses transmission errors between indoor PCB and adaptor PCB.

3.17 C4, C5, C9 Thermistor Abnormality

Diagnoses abnormalities related to C4, C5, and C9 thermistors.

3.18 C6 Defective Combination (between Indoor Unit PCB and Fan PCB)

Resolves issues from defective combinations between indoor PCB and fan PCB.

3.19 CC Humidity Sensor System Abnormality

Addresses abnormalities in the humidity sensor system.

3.20 CJ Remote Controller Thermistor Abnormality

Diagnoses abnormalities with the remote controller thermistor.

3.21 E0 Actuation of Safety Device

Covers issues related to safety device actuation.

3.22 E0 Activation of Outdoor Unit Protection Device

Addresses activation of outdoor unit protection devices.

3.23 E1 Outdoor Unit PCB Abnormality

Diagnoses abnormalities with the outdoor unit PCB.

3.24 E3 High Pressure System Abnormality

Resolves issues related to high pressure system abnormalities.

3.25 E3 Abnormally High Pressure Level (HPS)

Addresses abnormally high pressure levels indicated by HPS.

3.26 E3 High Pressure Abnormality (HPS)

Diagnoses high pressure abnormalities detected by HPS.

3.27 E3 Actuation of High Pressure Switch

Covers issues related to high pressure switch actuation.

3.28 E4 Low Pressure System Abnormality

Diagnoses abnormalities in the low pressure system.

3.29 E4 Actuation of Pressure Sensor

Addresses issues with pressure sensor actuation.

3.30 E4 Low Pressure Sensor System Abnormality

Covers abnormalities in the low pressure sensor system.

3.31 E4 Actuation of Low Pressure Sensor

Addresses issues with low pressure sensor actuation.