Service Diagnosis
Si20 - 701_B

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin FHYK71FJV1 and is the answer not in the manual?

Daikin FHYK71FJV1 Specifications

General IconGeneral
ModelFHYK71FJV1
CategoryAir Conditioner
Cooling Capacity7.1 kW
Heating Capacity8.0 kW
RefrigerantR32
Indoor Unit Dimensions (W x H x D)1, 280 x 235 x 680 mm
Outdoor Unit Dimensions (W x H x D)855 x 735 x 330 mm
Power Supply220-240V

Summary

Symptom-based Troubleshooting

Equipment does not Operate

Detailed troubleshooting steps for when the equipment fails to operate.

Indoor Unit Fan Operates, but Compressor does not Operate

Diagnosing issues where the indoor fan runs but the compressor does not.

Cooling / Heating Operation Starts but Stops Immediately

Troubleshooting for operations that start and then stop abruptly.

Equipment Operates but does not Provide Cooling

Diagnosing lack of cooling performance when the unit is operating.

Equipment Operates but does not Provide Heating

Diagnosing lack of heating performance when the unit is operating.

Troubleshooting by Remote Controller

Procedure of Self-diagnosis by Remote Controller

Steps for performing self-diagnosis using the remote controller.

Error Codes and Description

Comprehensive list and descriptions of error codes for indoor units.

Detailed Error Codes

In-depth explanations and troubleshooting for specific error codes.

A0 Error of External Protection Device

Troubleshooting for error code A0 related to external protection devices.

A1 Indoor Unit PCB Abnormality

Diagnosing issues related to indoor unit PCB abnormalities (Error A1).

A3 Drain Water Level System Abnormality

Troubleshooting for drain water level system abnormalities (Error A3).

A6 Indoor Unit Fan Motor Abnormality

Diagnosing abnormalities with the indoor unit fan motor (Error A6).

A6 Fan Motor (M1F) Lock, Overload

Troubleshooting fan motor lock or overload conditions (Error A6).

A7 Swing Flap Motor Abnormality / Lock

Diagnosing swing flap motor abnormalities or lock conditions (Error A7).

A8 Abnormal Power Supply Voltage

Troubleshooting abnormal power supply voltage issues (Error A8).

A9 Electronic Expansion Valve Coil (Y1E) Abnormality

Diagnosing abnormalities with the electronic expansion valve coil (Error A9).

AF Drain System Abnormality

Troubleshooting drain system abnormalities (Error AF).

AF Drain Level above Limit

Addressing issues where the drain level exceeds the limit (Error AF).

C1 Transmission Error (between Indoor Unit PCB and Fan PCB)

Diagnosing transmission errors between indoor unit PCB and fan PCB (Error C1).

C1 Transmission Error (between Indoor Unit PCB and Adaptor PCB)

Diagnosing transmission errors between indoor unit PCB and adaptor PCB (Error C1).

C4, C5, C9 Thermistor Abnormality

Troubleshooting thermistor abnormalities for codes C4, C5, C9.

C6 Defective Combination (between Indoor Unit PCB and Fan PCB)

Diagnosing defective combinations between indoor unit PCB and fan PCB (Error C6).

CC Humidity Sensor System Abnormality

Troubleshooting humidity sensor system abnormalities (Error CC).

CJ Remote Controller Thermistor Abnormality

Diagnosing remote controller thermistor abnormalities (Error CJ).

U0 Low Pressure Drop Due to Refrigerant Shortage or Electronic Expansion Valve Failure

Troubleshooting low pressure drop due to refrigerant shortage or EV failure (Error U0).

U0 Refrigerant Shortage

Diagnosing refrigerant shortage issues (Error U0).

U4 or UF Transmission Error (Between Indoor Unit and Outdoor Unit)

Troubleshooting transmission errors between indoor and outdoor units (Error U4/UF).

U4 Transmission Error Between Indoor Unit and Outdoor Unit

Diagnosing transmission errors between indoor and outdoor units (Error U4).

U4 Transmission Error between Indoor Unit and Outdoor Unit

Troubleshooting transmission errors between indoor and outdoor units (Error U4).

UE Transmission Error between Centralized Controller and Indoor Unit

Troubleshooting transmission errors between centralized controller and indoor unit (Error UE).

UF Transmission Error between Indoor and Outdoor Unit / Piping and Wiring Mismatch / Refrigerant Shortage

Diagnosing transmission errors, piping/wiring mismatches, or refrigerant shortages (Error UF).

UF Transmission System Abnormality (between Indoor and Outdoor Units)

Troubleshooting transmission system abnormalities between indoor and outdoor units (Error UF).