DAIKIN ROOM AIR CONDITIONER
OPERATION MANUAL AND
INSTALLATION MANUAL
MODELS
FT18HEV1K
FT24HEV1K
FT28HEV1K
FT18HEVLK
FT24HEVLK
FT30HEVLK
FTY18HEV1K
FTY24HEV1K
FTY28HEV1K
FTY18HEVLK
FTY24HEVLK
FTY30HEVLK
00_CV_3V007382-3F.indd 100_CV_3V007382-3F.indd 1 5/14/2010 5:31:08 PM5/14/2010 5:31:08 PM

Other manuals for Daikin FT18HEV1K

Questions and Answers

  • B
    Brian KingSep 4, 2025
    Why does my Daikin Air Conditioner indoor unit does not deliver air?
    • J
      james78Sep 4, 2025
      If the indoor unit of your Daikin Air Conditioner isn't delivering air: * In HEAT mode, air delivery is delayed until the indoor heat exchanger reaches the correct temperature (within 2 minutes). * In HEAT mode, during automatic defrost of the outdoor heat exchanger (when the outdoor temperature is cold), the indoor unit stops delivering air for 3-12 minutes. Water or vapor may be emitted during defrost. * In dehumidifying mode, the indoor fan will sometimes stop to prevent water condensation from being vaporized.
  • J
    Jill CarrSep 18, 2025
    Why is there a delay in operation after starting Daikin Air Conditioner?
    • S
      Sabrina MathisSep 18, 2025
      As a precaution, your Daikin Air Conditioner operation cannot be resumed for approximately 3 minutes after the air conditioner has stopped.
  • B
    burchjeffreySep 16, 2025
    Why does moisture gather on the air outlet vent of Daikin FT18HEV1K?
    • M
      Mark LarsonSep 16, 2025
      If moisture gathers on the air outlet vent of your Daikin Air Conditioner, it's likely because the unit is operating in high humidity for a long time, causing moisture to condense on the air outlet grill and drip off.
  • T
    Taylor WarnerSep 14, 2025
    Why does mist come out of the air outlet vent of Daikin FT18HEV1K?
    • A
      Amanda GlennSep 14, 2025
      The mist coming out of the air outlet vent in COOL mode on your Daikin Air Conditioner can happen if indoor temperatures and relative humidity are high, especially when air in the room is cooled down too quickly. This should decrease after operating for a while.
  • E
    Eric CarpenterSep 12, 2025
    What is the sound of water flowing during operation of Daikin FT18HEV1K Air Conditioner?
    • S
      Susan DavisSep 13, 2025
      The sound of water flowing you hear during the operation of your Daikin Air Conditioner is caused by the flowing of refrigerant. When the air conditioner is started or stopped, the compressor starts and sometimes creates gurgling sounds.
  • B
    Bryan RaySep 12, 2025
    Why is my Daikin FT18HEV1K Air Conditioner indoor unit not delivering air?
    • S
      Stephanie WilliamsSep 12, 2025
      If the indoor unit of your Daikin Air Conditioner isn't delivering air, this could be normal in HEAT mode until the indoor heat exchanger reaches the correct temperature (within 2 minutes). Also, in HEAT mode, when the outdoor temperature is cold, frost on the outdoor heat exchanger is defrosted automatically and the indoor unit stops delivering air for 3-12 minutes. In dehumidifying mode, the indoor fan will sometimes stop to prevent water condensation from being vaporized.
  • T
    Timothy AverySep 9, 2025
    What to do if my Daikin Air Conditioner does not operate?
    • H
      Heidi ThomasSep 9, 2025
      If your Daikin Air Conditioner isn't turning on, ensure that the power is on and the power cord is securely connected. Also, check whether the circuit protection device has been tripped. The voltage may be too high or too low. Finally, verify that the TIMER is being used correctly.
  • C
    Christopher HendersonSep 7, 2025
    Why does my Daikin Air Conditioner sometimes emit mist from the air outlet in COOL mode?
    • W
      whaasSep 7, 2025
      Mist coming from the air outlet vent of your Daikin Air Conditioner in COOL mode can happen if indoor temperatures and relative humidity are high, and the air is cooled too quickly. The temperatures and humidity should decrease after operating for a while.
  • J
    John HowardSep 5, 2025
    Why does my Daikin FT18HEV1K make a sound of water flowing during operation?
    • J
      Joan CrosbySep 5, 2025
      When your Daikin Air Conditioner starts or stops, the compressor starts and sometimes creates gurgling sounds due to the flowing of refrigerant.
  • J
    Jessica HoltAug 20, 2025
    Why is my Daikin FT18HEV1K cooling/heating not sufficient?
    • B
      Breanna HaleAug 21, 2025
      If your Daikin Air Conditioner isn't cooling or heating enough, check the temperature setting and ensure that the inlet and outlet vents are not blocked. Also, make sure the air filter is clean, windows and doors are closed, and the fan speed isn't set too low. Other heat or cold sources might also be contributing to the problem.

Summary

Operation Manual

Safety Precautions

Essential safety guidelines and warnings for operating the unit, covering warnings and cautions.

Introduction to Basic Functions

Explains the fundamental cooling, heating, and defrosting operations of the air conditioner.

Description of Parts

Identifies and illustrates the components of the indoor and outdoor units.

Remote Control Operation

Details how to use the remote controller for various functions, settings, and operations.

Emergency Operation

Provides instructions for operating the unit manually using the manual switch in emergencies.

Cleaning and Maintenance

Guides on regular cleaning of the front panel and air filters for optimal performance.

Troubleshooting

Lists common problems and their solutions for user diagnosis and quick fixes.

Installation Manual

Safety Precautions

Critical safety measures and warnings specific to unit installation, covering electrical and refrigerant safety.

Installation Dimensions

Specifies required clearances and dimensions for correct installation of indoor and outdoor units.

Indoor Unit Installation

Step-by-step guide for mounting the rear panel, piping, and wiring of the indoor unit.

Outdoor Unit Installation

Instructions for electrical wiring, air leakage test, and condensation drain for the outdoor unit.

Installation and Test Operation Checklist

A checklist for verifying correct installation and performing initial test operations.

Specifications

Technical data and performance ratings for various Daikin air conditioner models.

Daikin FT18HEV1K Specifications

General IconGeneral
BrandDaikin
ModelFT18HEV1K
CategoryAir Conditioner
LanguageEnglish

Related product manuals