Outdoor Unit (50 / 52 / 58 / 68 / 75 Class) Si12-411A
252 Removal Procedure
2.6 Removal of Four Way Valve Coil, Solenoid Valve Coil,
Electronic Expansion Valve Coil and Thermistor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1
Remove 1 screw of the
four way valve coil.
2
Remove one screw of
the solenoid valve coil.
3
Remove the electronic
expansion valve coil for
each room.
Place the thermistor so that
its end comes up to the end
of the presser spring.
4
Release the thermistor
presser spring, and
remove the discharge
pipe thermistor.
Be careful not to lose the
presser spring for the
discharge pipe thermistor.

Table of Contents