26
NOTE
Check
Before a long idle period
1. Operate the “FAN only” for several hours on a fine day to dry out the
inside.
Press “MODE” button and select “FAN” operation.
Press “ON/OFF” button and start operation.
2. After operation stops, turn off the breaker for the room air conditioner.
3. Clean the air filters and set them again.
4. Take out batteries from the remote controller.
NOTE) When a multi outdoor unit is connected, make sure the heating operation is not
used at the other room before you use the fan operation. (page 22.)
Operation with dirty filters:
(1) cannot deodorize the air. (2) cannot clean the air.
(3) results in poor heating or cooling. (4) may cause odour.
To order Titanium Apatite Photocatalytic Air-Purifying Filter contact to the service shop
there you bought the air conditioner.
Dispose of old filters as non-flammable waste.
Check that the base, stand and other fittings of the outdoor unit are not decayed or corroded.
Check that nothing blocks the air inlets and the outlets of the indoor unit and the outdoor unit.
Check that the drain comes smoothly out of the drain hose during COOL or DRY operation.
If no drain water is seen, water may be leaking from the indoor unit. Stop operation and consult the
service shop if this is the case.
Item Part No.
Titanium Apatite Photocatalytic Air-Purifying Filter
(without frame) 1 set
KAF952B42
01_EN_3P192025-2.fm Page 26 Wednesday, October 11, 2006 4:17 PM