7
Technical Information
Service Manual
The above data is subject to change without notice; please refer to the nameplate of the unit.
Outdoor Unit
Model of Outdoor Unit RXS24SL216
Outdoor Unit Product Code CB425W07700_L84775
Compressor Manufacturer/Trademark ZHUHAI LANDA COMPRESSOR CO.,LTD
Compressor Model QXA-B141zF030A
Compressor Oil RB68EP
Compressor Type Rotary
Compressor Locked Rotor Amp (L.R.A) A 25
Compressor RLA A 12.18
Compressor Power Input W 1440
Overload Protector NT11L-6233 or KSD115
or HPC115/95U1
Throttling Method Electron expansion valve
Operation temp ºF 60.8~86
Ambient temp (cooling) ºF 0~115
Ambient temp (heating) ºF -4~75
Condenser Form Aluminum Fin-copper Tube
Pipe Diameter inch Φ3/8
Rows-n Gap inch 2-1/16
Coil Length (LXDXW) inch 33 5/16X1 3/4X26
Fan Motor Speed rpm 800
Output of Fan Motor W 60
Fan Motor RLA A 0.4
Fan Motor Capacitor μF /
Air Flow Volume of Outdoor Unit CFM 3200
Fan Type Axial-ow
Fan Diameter inch Φ20 1/2
Defrosting Method Automatic Defrosting
Climate Type T1
Isolation I
Moisture Protection IPX4
Permissible Excessive Operating
Pressure for the Discharge Side
ISPG 550
Permissible Excessive Operating
Pressure for the Suction Side
ISPG 240
Sound Pressure Level (H/M/L) dB (A) 58/-/-
Sound Power Level (H/M/L) dB (A) 68/-/-
Dimension (WXHXD) inch 38X27 9/16X15 5/8
Dimension of Carton Box (LXWXH) inch 40 3/8X17 7/8X29
Dimension of Package (LXWXH) inch 40 1/2X18X29 1/2
Net Weight Ib 103.62
Gross Weight Ib 113.54
Refrigerant R410A
Refrigerant Charge oz 56.4
Connection
Pipe
Length ft 24.6
Gas Additional Charge oz/ft 0.2
Outer Diameter Liquid Pipe inch Φ1/4
Outer Diameter Gas Pipe inch Φ5/8
Max Distance Height ft 32.8
Max Distance Length ft 82
Note:The connection pipe applies metric diameter.