EasyManua.ls Logo

Daikin FTKS20DVMW(L) - User Manual

Daikin FTKS20DVMW(L)
228 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SiEBE04-507A
Service Manual
/ Inverter Pair Wall Mounted Type D-Series
SiENBE04-507A
Ser vice
Manual
[Applied Models]
!Inverter Pair : Cooling Only
!Inverter Pair : Heat Pump
Inverter Pair
Wall Mounted Type D-Series
Daikin Europe N.V. participates in the Eurovent
Certification Programme for Air Conditioners (AC),
Liquid Chilling Packages (LCP) and Fan Coil Units (FC);
the certified data of certified models are listed in the
Eurovent Directory.
ISO14001 assures an effective environmental
management system in order to help protect human
health and the environment from the potential impact
of our activities, products and services and to assist in
maintaining and improving the quality of the
environment.
Daikin Europe N.V. is approved by LRQA for its Quality
Management System in accordance with the ISO9001
standard. ISO9001 pertains to quality assurance
regarding design, development, manufacturing as well
as to services related to the product.
Daikin units comply with the European regulations that
guarantee the safety of the product.
SiENBE04-507A • 06/2007 • Copyright © Daikin
Printed in Belgium by Lannoo, a company whose concern for the environment
is set in the EMAS and ISO 14001 systems. www.lannooprint.be
ÉSiENBE04-507AÄËÍ
Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende - Belgium
www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende
"The present publication is drawn up by way of information only
and does not constitute an offer binding upon Daikin Europe N.V..
Daikin Europe N.V. has compiled the content of this publication to
the best of its knowledge. No express or implied warranty is given
for the completeness, accuracy, reliability or fitness for particular
purpose of its content and the products and services presented
therein. Specifications are subject to change without prior notice.
Daikin Europe N.V. explicitly rejects any liability for any direct or
indirect damage, In the broadest sense, arising from or related to
the use and/or interpretation of this publication. All content is
copyrighted by Daikin Europe N.V.."
Daikin’s unique position as a manufacturer of air
conditioning equipment, compressors and
refrigerants has led to its close involvement in
environmental issues.
For several years Daikin has had the intension to
become a leader in the provision of products
that have limited impact on the environment.
This challenge demands the eco design and
development of a wide range of products and
an energy management system, resulting in
energy conservation and a reduction of waste.

Table of Contents

Questions and Answers

  • A
    Alfred SmithJul 31, 2025
    What to do if my Daikin Air Conditioner indoor unit smells bad?
    • O
      oarnoldAug 1, 2025
      If your Daikin Air Conditioner's indoor unit is emitting an odor, it is recommended to have the indoor unit cleaned by a technician.
  • K
    Kyle HensonAug 6, 2025
    Why is my Daikin FTKS20DVMW(L) outdoor unit emitting water or steam?
    • K
      Kaitlin WalkerAug 6, 2025
      If your Daikin Air Conditioner's outdoor unit is emitting water or steam, this is normal. In HEAT mode, frost on the outdoor unit melts into water or steam during defrost operation. In COOL or DRY mode, moisture in the air condenses into water on the cool surface of the outdoor unit piping and drips.
  • J
    John WoodAug 11, 2025
    Why does mist come out of my Daikin Air Conditioner indoor unit?
    • M
      Madeline BonillaAug 11, 2025
      Mists coming out of the Daikin Air Conditioner's indoor unit can occur when the air in the room is cooled into mist by the cold airflow during cooling operation.
  • E
    Erin HermanAug 16, 2025
    Why does the outdoor fan on my Daikin Air Conditioner keep running when it's off?
    • C
      chapmankevinAug 16, 2025
      If the outdoor fan of your Daikin Air Conditioner rotates even when the unit is not in operation, this is normal. After stopping the operation, the fan may continue rotating for 60 seconds for system protection. Also, when the outdoor temperature is very high, the fan might start rotating for system protection.
  • V
    Veronica SantiagoAug 21, 2025
    What to do if my Daikin FTKS20DVMW(L) operation stopped suddenly but the OPERATION lamp is on?
    • J
      Joseph ForbesAug 21, 2025
      If your Daikin Air Conditioner stops suddenly and the OPERATION lamp is on, it will automatically resume operation in about 3 minutes.
  • T
    Tamara CampbellAug 26, 2025
    What to do if my Daikin Air Conditioner heating stops and I hear a flowing sound?
    • E
      Eric AvilaAug 26, 2025
      If the heating operation of your Daikin Air Conditioner stops suddenly and a flowing sound is heard, please wait for about 3 to 8 minutes.

Summary

Introduction and Safety

Safety Cautions for Operation

Essential safety guidelines and warnings for operating the air conditioning unit and during repairs.

Part 2 Specifications

Cooling Only Model Specifications

Detailed technical specifications for cooling-only models, including indoor and outdoor unit details.

Heat Pump Model Specifications

Detailed technical specifications for heat pump models, including indoor and outdoor unit details.

Part 3 Printed Circuit Board Connector Wiring Diagram

Part 4 Function and Control

Part 5 System Configuration

Instruction and Safety Precautions

Guidance on safe operation, handling, and installation site considerations.

Part 6 Service Diagnosis

Troubleshooting Error Codes and Descriptions

Lists error codes displayed on the remote and their descriptions for diagnosing issues.

Part 7 Removal Procedure

Daikin FTKS20DVMW(L) Specifications

General IconGeneral
BrandDaikin
ModelFTKS20DVMW(L)
CategoryAir Conditioner
LanguageEnglish