INSTALLATION MANUAL
R410A SPLIT SERIES
Installation Manual
R410A Split Series
English
Manual de instalación
Serie Split R410A
Español
Manuel d’installation
Série split R410A
Français
DAIKIN ROOM AIR CONDITIONER
3P601788-2 G
MODELS
FTX09BXVJU
FTX12BXVJU
FTX18BXVJU
FTX24BXVJU
RX09BXVJU
RX12BXVJU
RX18BXVJU
RX24BXVJU
FTK09BXVJU
FTK12BXVJU
FTK18BXVJU
FTK24BXVJU
RK09BXVJU
RK12BXVJU
RK18BXVJU
RK24BXVJU
FTXB09BXVJU
FTXB12BXVJU
FTXB18BXVJU
FTXB24BXVJU
RXB09BXVJU
RXB12BXVJU
RXB18BXVJU
RXB24BXVJU
01_IM-FTX&FTK-DAIKIN_3P601788-2 G-EN.indb 101_IM-FTX&FTK-DAIKIN_3P601788-2 G-EN.indb 1 14/10/2022 10:25:00 AM14/10/2022 10:25:00 AM

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Daikin FTX12BXVJU and is the answer not in the manual?

Summary

Safety Precautions

Installation Work Precautions

Warns against DIY installation and emphasizes qualified personnel and proper foundation.

Wiring Safety

Covers electrical work, dedicated circuits, wire types, and connections for safety.

Refrigerant Handling Safety

Precautions regarding refrigerant leaks, toxic gas, and pump-down procedures.

Electrical and Wiring Hazards

Warns about touching moving parts, power supply, and interference with electronic devices.

Flammable Gas and Installation Safety

Warns against installing near flammable gas and importance of drain piping.

Refrigerant Circuit Safety

Covers flare nut tightening, overcharging, sharp edges, and fan operation.

Refrigerant Handling by Professionals

States that only qualified personnel can handle refrigerant.

Choosing an Installation Site

Indoor Installation Guideline

Drain Piping

Wiring

Wiring Diagram and Recommendations

Shows wiring connections between indoor and outdoor units and recommended wire types.

Wiring Safety Precautions

Critical warnings about electrical connections, terminals, and covers.

Wiring Safety and Circuit Breaker

Reinforces wiring safety and the need for circuit breakers.

Outdoor Installation Guideline

Refrigerant Piping

Flare Nut Tightening and Oil Application

Instructions on using torque wrenches and applying oil for flare connections.

R410 A Refrigerant Special Precautions

Key safety and handling advice specific to R410A refrigerant.

Purging Air and Checking Gas Leakage

Purging and Leak Testing Warnings

Critical warnings about mixing substances, ventilation, and recovery.

Leak Testing and Evacuation Procedure

Steps for pressurizing, leak testing, and evacuating the system with a vacuum pump.

Refilling Refrigerant

R410 A Refrigerant Filling Precautions

Advice on filling refrigerant from the liquid pipe and using R410A tools.

Pump Down Operation

Pump Down Safety Warnings

Dangers of refrigerant leakage and compressor damage during pump down.

Electrical Wiring Connection

Commissioning

Maintenance and Service

Summary

Safety Precautions

Installation Work Precautions

Warns against DIY installation and emphasizes qualified personnel and proper foundation.

Wiring Safety

Covers electrical work, dedicated circuits, wire types, and connections for safety.

Refrigerant Handling Safety

Precautions regarding refrigerant leaks, toxic gas, and pump-down procedures.

Electrical and Wiring Hazards

Warns about touching moving parts, power supply, and interference with electronic devices.

Flammable Gas and Installation Safety

Warns against installing near flammable gas and importance of drain piping.

Refrigerant Circuit Safety

Covers flare nut tightening, overcharging, sharp edges, and fan operation.

Refrigerant Handling by Professionals

States that only qualified personnel can handle refrigerant.

Choosing an Installation Site

Indoor Installation Guideline

Drain Piping

Wiring

Wiring Diagram and Recommendations

Shows wiring connections between indoor and outdoor units and recommended wire types.

Wiring Safety Precautions

Critical warnings about electrical connections, terminals, and covers.

Wiring Safety and Circuit Breaker

Reinforces wiring safety and the need for circuit breakers.

Outdoor Installation Guideline

Refrigerant Piping

Flare Nut Tightening and Oil Application

Instructions on using torque wrenches and applying oil for flare connections.

R410 A Refrigerant Special Precautions

Key safety and handling advice specific to R410A refrigerant.

Purging Air and Checking Gas Leakage

Purging and Leak Testing Warnings

Critical warnings about mixing substances, ventilation, and recovery.

Leak Testing and Evacuation Procedure

Steps for pressurizing, leak testing, and evacuating the system with a vacuum pump.

Refilling Refrigerant

R410 A Refrigerant Filling Precautions

Advice on filling refrigerant from the liquid pipe and using R410A tools.

Pump Down Operation

Pump Down Safety Warnings

Dangers of refrigerant leakage and compressor damage during pump down.

Electrical Wiring Connection

Commissioning

Maintenance and Service

Daikin FTX12BXVJU Specifications