Category | Heat Pump |
---|---|
Model | FTX25JAV1NB |
Cooling Capacity | 2.5 kW |
Heating Capacity | 3.2 kW |
Weight (Indoor Unit) | 9 kg |
Indoor Unit Weight | 9 kg |
Power Supply | 220-240V / 50Hz |
Details PCB connectors for Branch Provider units BPMK928B42 and B43.
Wiring diagrams for various outdoor unit models.
Wiring diagrams for specific FTK, FTX, FTXD, and FVX series.
Wiring diagrams for FTK, FTKD, FTX, and FTXD series.
Wiring diagrams for CDX and CDK HAV series indoor units.
Wiring diagrams for FLK and FLX series indoor units.
Wiring diagrams for FHYC KV series indoor units.
Wiring diagrams for FDYM series indoor units.
Details the refrigerant system and components of outdoor units.
Explains the refrigerant circuit and functional parts of outdoor units.
Lists and explains protective devices, thermistors, and sensors.
Overview of the system's control logic and operations.
Provides a summary of the overall system control strategy.
Explains standby control procedures when power is applied.
Describes standby operations during cooling and heating startup.
Details the equalizing control process for system stability.
Explains how the initial operating frequency is determined.
Describes the procedure for oil return operations.
Details the defrost operation cycle and conditions.
Explains the pre-equalization standby operation process.
Provides details on the equalizing control process.
Explains the system's capacity control mechanisms.
Details the peak cut control function to prevent high pressure.
Describes the freeze-up prevention control for indoor heat exchangers.
Explains how gas shortage malfunctions are detected and handled.
Details the control logic for discharge pipe temperature.
Explains the input current control mechanisms.
Details the wet protection control function.
Describes cooling for electric parts and fin temperature control.
Explains the differential pressure control for fan speed.
Details the function for year-round cooling operation.
Describes the nighttime low noise control features.
Explains the PI control mechanism for frequency adjustment.
Details the warm-up function for compressor startup.
Explains compressor protection controls during startup.
Describes fan control strategies under various conditions.
Details the control of motorized valves in the outdoor unit.
Explains the subcooling control for outdoor units during cooling.
Details the control of motorized valves for BP units.
Explains isothermal control for gas pipes during cooling.
Details the SH control for cooling operations.
Explains the SC control for heating operations.
Describes isothermal control for heat exchangers in heating mode.
Details BP unit valve control for high discharge pipe temperature.
Explains isothermal control for heat exchangers between BP units in heating.
Describes isothermal control for gas pipes between BP units.
Details BP unit valve control based on target discharge pipe temperature.
Explains the operation and security of the 4-way valve.
Details the pump down operation procedure.