This document is an operation manual for Daikin Room Air Conditioners, specifically models FTX25KNV1B and FTX35KNV1B, featuring INVERTER technology for year-round comfort. The manual provides comprehensive instructions on the device's functions, usage, and maintenance.
The Daikin Room Air Conditioner is designed to provide enhanced comfort and energy savings through various operational modes and features. Its core function is to regulate room temperature and humidity, offering cooling, heating, drying, and fan-only operations. The INVERTER technology allows for efficient operation by adjusting the compressor speed to maintain desired temperatures, leading to reduced energy consumption.
The unit includes a COMFORT AIRFLOW function, which optimizes airflow direction to prevent cold or warm air from blowing directly onto occupants. In COOL operation, airflow is directed upward, while in HEAT operation, it is directed downward. This feature aims to create a more comfortable environment by distributing air evenly without causing discomfort from direct drafts.
Another key function is ECONO operation, which limits the maximum power consumption of the air conditioner. This is particularly useful when multiple electrical devices are operating simultaneously on a shared electrical circuit, helping to prevent circuit breakers from tripping. This function ensures efficient operation while managing the overall electrical load.
The POWERFUL operation function allows the air conditioner to quickly maximize its cooling or heating effect. In this mode, the unit operates at its maximum capacity for a set period (typically 20 minutes) to rapidly achieve the desired temperature. After this period, the system automatically reverts to its previous settings, providing a quick boost when needed.
The air conditioner also features TIMER operation, enabling users to automatically switch the unit on or off at predetermined times. This includes ON TIMER and OFF TIMER functions, which can be used independently or combined to schedule operation, for example, to turn on before arrival or turn off after sleeping. The NIGHT SET mode, activated with the OFF TIMER, automatically adjusts the temperature setting (0.5°C up in COOL, 2.0°C down in HEAT) to prevent excessive cooling or heating during sleeping hours, further enhancing comfort and energy efficiency.
The air conditioner is controlled via a remote controller, which displays current settings on an LCD screen. The remote controller allows for easy selection of various operation modes:
Users can adjust the airflow rate to increase comfort, with settings ranging from "Indoor unit quiet" to "Airflow rate 1-5 (Low to High)." A "quiet operation" mode is available for reduced noise levels. The airflow direction can also be adjusted. The remote controller allows for automatic up and down swing of the flap (horizontal blade) or setting it to a desired fixed position. Vertical louvers can be manually adjusted by holding their knobs.
The remote controller also includes a Fahrenheit/Celsius display switch, allowing users to toggle between temperature units by pressing the "TEMP °F/°C" and "ON (TIMER)" buttons simultaneously for about 5 seconds.
For convenience, an indoor unit ON/OFF switch is located on the unit itself, which can be used to start or stop operation if the remote controller is unavailable. When operated via this switch, the unit defaults to AUTO mode, 25°C temperature setting, and AUTO airflow rate.
Regular care and cleaning are essential for maintaining the air conditioner's performance and longevity. The manual outlines a simple cleaning routine for various parts:
The manual emphasizes several precautions for cleaning, such as stopping operation and turning off the circuit breaker before cleaning, avoiding contact with aluminum fins, and not using hot water (above 40°C), volatile liquids (like benzene or thinner), polishing compounds, or rough scrubbing brushes.
For long periods of non-use, such as during spring or autumn, it is recommended to operate the unit in FAN ONLY mode for several hours to dry out the inside, then turn off the circuit breaker and remove the batteries from the remote controller.
The manual also recommends periodical maintenance by a qualified contractor, in addition to user cleaning, especially if the air conditioner's interior becomes foul after several seasons of use, which can lead to poor performance.
Troubleshooting information is provided to help users identify and resolve common issues, such as the unit not operating, sudden stops, or unusual sounds. It also includes instructions for fault diagnosis using the remote controller, which can display error codes to assist in identifying problems.
| Cooling Capacity | 2.5 kW |
|---|---|
| Heating Capacity | 3.2 kW |
| Seasonal Energy Efficiency Ratio (SEER) | 6.1 |
| Power Supply | 220-240V, 50Hz |
| Indoor Unit Dimensions (HxWxD) | 290 x 800 x 200 mm |
| Outdoor Unit Dimensions (HxWxD) | 540 x 780 x 290 mm |
| Weight (Indoor Unit) | 9 kg |
| Refrigerant | R32 |
| Type | Split System |