2 | Components
Service manual
122
FTXA20~50A(W)(S)(T) + FTXA20~50B(B)(S)(T) + RXA42+50A +
RXA20~35A(9) + RXA42+50B
Split Stylish R32
ESIE18-03D – 2021.05
a
a Compressor sound insulation
To remove the switch box
INFORMATION
This procedure is just an example and may differ on some details for your actual unit.
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see "2.14Plate work"[4120].
1 Remove the insulation on the upper side of the switch box.
ab
a Insulation
b Main PCB
2 Disconnect all connectors from the main PCB.
3 Disconnect the electrical power supply wiring from the wire terminals.