6 | Unit installation
Installer reference guide
28
FTXP-M + FTXF-D + FTXF-A + ATXF-A
Daikin room air conditioner
4P513661-12L – 2021.07
a
b
a
b
a Insulation fixing screw
b Drain hose
4 Attach the drain hose to the refrigerant piping bottom side using adhesive
vinyl tape.
A
B
C
b
a
A Left-side piping
B Left-back piping
C Left-bottom piping
a Remove the pipe port cover here for left-side piping
b Remove the pipe port cover here for left-bottom piping
6.4.4 To check for water leaks
1 Remove the air filters.
2 Gradually pour approximately 1 l of water in the drain pan, and check for
water leaks.