Ŷ
To change the temperature setting
Press .
The displayed items on the LCD will change whenever either one of the buttons is
pressed.
COOL operation HEAT operation AUTO operation DRY or FAN ONLY operation
18.0-32.0°C 10.0-30.0°C 18.0-30.0°C
The temperature setting is
not available.
Press
to raise the temperature and press to lower the
temperature 1.0°C each press.
Ŷ
Operating conditions
Ŷ
Recommended temperature setting
For cooling: 26.0-28.0°C
For heating: 20.0-24.0°C
Ŷ
Tips for saving energy
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) ef
Clogged air filters cause inefficient operation and waste energy. Clean them once in about every 2 weeks.
fect.
Ŷ
Notes on the operating conditions
The air conditioner always consumes a small amount of electricity even while it is not operating.
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker off.
Use the air conditioner in the following conditions.
MODE Operating conditions If operation is continued out of this range
COOL
:erutarepmet roodtuO -10.0 ~ 46.0°C
Indoor temperature : 18.0-32.0°C
Indoor humidity : 80% max.
A safety device may work to stop the operation.
Condensation may occur on the indoor unit and drip.
HEAT
:erutarepmet roodtuO -15.0 ~ 24.0°C
Indoor temperature : 10.0-30.0°C
A safety device may work to stop the operation.
DRY
:erutarepmet roodtuO -10.0 ~ 46.0°C
Indoor temperature : 18.0-32.0°C
Indoor humidity : 80% max.
A safety device may work to stop the operation.
Condensation may occur on the indoor unit and drip.
Operation outside this humidity or temperature range may cause a safety device to disable the system.
P
P
10