EasyManua.ls Logo

Daikin FTXF71D2V1B - To Fix the Unit on the Mounting Plate; Closing the Unit; To Close the Electrical Wiring Box Cover; To Re-Install the Front Grille

Daikin FTXF71D2V1B
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9 | Finishing the indoor unit installation
Installer reference guide
40
FTXP-M + FTXF-D + FTXF-A + ATXF-A
Daikin room air conditioner
4P513661-12L – 2021.07
2 Pass the drain hose and refrigerant pipes through the wall hole.
9.3 To fix the unit on the mounting plate
1 Set the indoor unit on the mounting plate hooks. Use the " " marks as a
guide.
2 Press the bottom frame of the unit with both hands to set it on the bottom
hooks of the mounting plate. Make sure that the wires do NOT get squeezed
anywhere.
Note: Take care that the interconnection cable does NOT get caught in the indoor
unit.
3 Press the bottom edge of the indoor unit with both hands until it is firmly
caught by the mounting plate hooks.
4 Secure the indoor unit to the mounting plate using 2 indoor unit fixing screws
M4×12L (accessory).
9.4 Closing the unit
9.4.1 To close the electrical wiring box cover
1 Hook the electrical wiring box cover in the bottom tab.
2 Close it, and slide the cover into the 2 upper tabs.
3 Fix the electrical wiring box with 1 screw.
9.4.2 To re-install the front grille
1 Install the front grille and firmly engage the 3 upper hooks.
2 Install 2 screws back on the front grille.
3 Install the air filter and then mount the front panel.
9.4.3 To close the service cover
1 Place the service cover to its original place on the unit.

Table of Contents

Other manuals for Daikin FTXF71D2V1B

Related product manuals