PCBs / Swing Motor Si041552E
10 Removal Procedure
4 Remove the connector
[S26] and release the
harnesses from the 3
hooks.
[S26]: display PCB
When reassembling, pass
the harness of the connector
[S26] under this hook and
the 3 wires.
5 Unfasten the 4 hooks
and remove the control
PCB.
When reassembling, be sure
to fit the control PCB to the 4
projections.
Step Procedure Points
3 wires Hook
(R21844)
Projection
(R21858)

Other manuals for Daikin FTXN09NMVJU