Electrical Box Si041552E
6 Removal Procedure
2 Pull out the indoor heat
exchanger thermistor.
Be careful not to lose the clip
of the thermistor.
The position of the indoor
heat exchanger thermistor
varies depending on the
model.
3 Release the earth /
ground wires and the
thermistor harness from
the front and the back
slits at the top of the
electrical box.
When reassembling, be sure
to insert the earth / ground
wires in the front slit and
yellow / green wire is above
the green wire and insert the
thermistor harness in the
back slit.
4 Unfasten the 4 hooks
and remove the
electrical box cover.
When reassembling, make
sure that the 4 hooks are
securely fastened.
Step Procedure Points
Indoor heat exchanger thermistor
(R21831)
Clip
(R11268)
Electrical box
Earth / ground wire Thermistor harness Slit
(R21832)
Front slit
Yellow / green
Green
Back slit
Thermistor
harness
(R21857)
Electrical box cover
Hook
(R21833)