Removal of PCBs (Pattern 1) Si041137
16 Removal Procedure
3
Remove the signal
receiver unit.
4. Remove the
INTELLIGENT EYE
sensor PCB.
1
Unfasten the 3 hooks
and remove the
INTELLIGENT EYE
sensor PCB.
2
Disconnect the
connector [S26] from
the INTELLIGENT EYE
sensor PCB.
Step
Procedure Points
(R12278)
Hook
(R8088)
Signal receiver unit
(R8092)
INTELLIGENT EYE
sensor PCB
(R8093)
[S26]