What to do if the power cord of Daikin Air conditioning is abnormally hot or damaged?
- PPatricia GarciaSep 8, 2025
If the power cord is abnormally hot or damaged, turn the breaker OFF and call the service shop.

What to do if the power cord of Daikin Air conditioning is abnormally hot or damaged?
If the power cord is abnormally hot or damaged, turn the breaker OFF and call the service shop.
Why is my Daikin Air conditioning cooling/heating effect poor?
The cooling or heating effect might be poor due to several reasons. Check if the air filters are clean. Ensure there is nothing blocking the air inlet or outlet of the indoor and outdoor units. Verify that the temperature setting is appropriate. Make sure the windows and doors are closed. Confirm that the airflow rate and direction are set correctly. Also, check if the unit is set to INTELLIGENT EYE mode.
What to do if my Daikin Air conditioning does not operate and the OPERATION lamp is off?
If your Daikin air conditioner isn't operating and the OPERATION lamp is off, check the following: Has a breaker turned OFF or a fuse blown? Is there a power failure? Are batteries properly set in the remote controller? Is the timer setting correct?
What to do if my Daikin FTXS35CVMB8 heating stops suddenly?
The system is likely removing frost from the outdoor unit. You should wait for about 3 to 8 minutes.
Why does my Daikin FTXS35CVMB8 smell?
The Daikin Air Conditioner may emit odors because smells from the room, furniture, or cigarettes have been absorbed into the unit and are being discharged with the airflow. It is recommended to have the indoor unit cleaned by a technician. Consult the service shop where you bought the air conditioner.
How to stop the bad odor from my Daikin Air conditioning indoor unit?
If the indoor unit gives out an odor, it is recommended to have the indoor unit washed by a technician. Consult the service shop where you bought the air conditioner.
What to do if an abnormality (such as a burning smell) occurs with Daikin Air conditioning?
If an abnormality, such as a burning smell, occurs, turn the breaker OFF and call the service shop.
What to do if there is a burning smell coming from Daikin Air conditioning?
If you notice a burning smell, immediately turn the breaker OFF and call the service shop.
What to do if I hear an abnormal sound during Daikin Air conditioning operation?
If you hear an abnormal sound during operation, turn the breaker OFF and call the service shop.
Why is my Daikin FTXS35CVMB8 outdoor unit leaking water?
In HEAT mode, the frost on the outdoor unit melts into water or steam during defrost operation. In COOL or DRY mode, moisture in the air condenses into water on the cool surface of the outdoor unit piping and drips.
| Brand | Daikin |
|---|---|
| Model | FTXS35CVMB8 |
| Category | Air Conditioner |
| Language | English |
Lists functions available for cooling-only air conditioner models.
Lists functions specific to heat pump air conditioner models.
Details technical specifications for various unit types.
Details specifications for indoor units in cooling-only mode.
Details specifications for outdoor units in cooling-only mode.
Details specifications for indoor units in heat pump mode.
Details specifications for outdoor units in heat pump mode.
Illustrates the layout and connections of PCBs.
Wiring diagram for wall-mounted indoor units of 20/25/35 class.
Wiring diagram for wall-mounted indoor units of 50/60/71 class.
Wiring diagram for duct-connected indoor units.
Wiring diagram for floor/ceiling suspended dual type indoor units.
Wiring diagram for floor standing type indoor units.
Wiring diagram for outdoor units.
Outlines critical safety warnings and cautions for installation and operation.
Lists common operational problems and their corresponding checks/measures.
Lists error codes displayed on the remote controller and their meanings.
Details error codes and their corresponding fault descriptions.
Detailed troubleshooting steps for various system malfunctions.
Troubleshooting specific to indoor unit faults.
Troubleshooting specific to outdoor unit faults.
Troubleshooting related to freeze-up protection and high pressure control.
Troubleshooting fan motor and associated component issues.
Diagnosing problems related to indoor unit thermistors.
Diagnosing communication errors between indoor and outdoor units.
Details troubleshooting for the indoor unit's freeze-up protection.
Troubleshooting compressor overload issues.
Diagnosing and resolving compressor lock issues.
Diagnosing and addressing over current detection faults.
Troubleshooting issues with the four-way valve.
Diagnosing problems with outdoor unit thermistors.
Troubleshooting over current detection in the inverter DC section.
Diagnosing and resolving refrigerant shortage or insufficient gas conditions.
Procedures for checking the electronic expansion valve.
Checks the performance and continuity of the four-way valve.
Measures thermistor resistance against standard values.
Procedure for safely removing the compressor unit.
Steps for safely removing the compressor unit.