EasyManua.ls Logo

Daikin FTYN25LV1B - LED INDICATOR LIGHTS: OPERATION AND FAULTS; Fault Code Reference

Daikin FTYN25LV1B
156 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-14
LED Indicator Lights: Normal Operation And Fault Conditions For Heat Pump Unit
Note: The unit will not detect sensor missing when the compressor is ON.
COOL/HEAT
(GREEN/RED)
Normal Operation/Fault Indication Action Error Code
Green
Cool mode - -
Red
Heat mode - -
Red
Auto mode in Heating operation - -
Green
Auto mode in Cooling operation - -
Timer on - -
Sleep mode on - -
Fan mode on - -
Dry mode on - -
1 time
Room air sensor contact
Loose/Short
Call your dealer Blink E1
3 times
Outdoor coil sensor open Call your dealer Blink E3
2 times
Indoor coil sensor open Call your dealer Blink E2
1 time
Compressor overload/ Indoor coil sensor short/
outdoor coil sensor short
Call your dealer Blink E4
Red
Defrost operation - -
3 times
Low Refrigerant Charge/Gas Leak/Outdoor
Abnormal
Call your dealer Blink E5
6 times
Hardware error (tact switch pin short) Call your dealer Blink E8
4 times
No feedback from indoor fan Call your dealer Blink E9
5 times
EEPROM error Call your dealer Blink EE
ON
ON or OFF
Blinking
Blink N times
Blink continuously
ON
OFF
12N 12N
500ms 500ms
3 seconds
ON
OFF
500ms 500ms
1 EN-5WMJ-1211(0)Daikin.indd 141 EN-5WMJ-1211(0)Daikin.indd 14 1/12/12 1:44:39 PM1/12/12 1:44:39 PM