9
To set the clock
1. Press “CLOCK button”.
is displayed.
blinks.
2. Press “TIMER setting button”
to set the clock to the present
time.
Holding down “ ” or “ ” button rap-
idly increases or decreases the time dis-
play.
3. Press “CLOCK button”.
blinks.
Turn the breaker ON
Turning ON the breaker opens the flap,
then closes it again.
(This is a normal procedure.)
NOTE
Tips for saving energy
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy.
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating)
effect.
Clogged air filters cause inefficient operation and waste energy. Clean them once in about every two weeks.
Please note
The air conditioner always consumes 15-35 watts of electricity even while it is not operating.
If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker OFF.
Use the air conditioner in the following conditions.
Operation outside this humidity or temperature range may cause a safety device to disable the system.
1, 3
2
Recommended temperature setting
For cooling: 26°C – 28°C
For heating: 20°C – 24°C
Mode Operating conditions If operation is continued out of this range
COOL
Outdoor temperature: –10 to 46°C
Indoor temperature: 18 to 32°C
Indoor humidity: 80% max.
A safety device may work to stop the operation.
Condensation may occur on the indoor unit and drip.
HEAT
Outdoor temperature: –15 to 18°C
Indoor temperature: 14 to 28°C
A safety device may work to stop the operation.
DRY
Outdoor temperature: –10 to 46°C
Indoor temperature: 18 to 32°C
Indoor humidity: 80% max.
A safety device may work to stop the operation.
Condensation may occur on the indoor unit and drip.
01_En_3P190111-2B.fm Page 9 Wednesday, February 28, 2007 3:13 PM

Other manuals for Daikin FTYN50FV1B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin FTYN50FV1B and is the answer not in the manual?

Daikin FTYN50FV1B Specifications

General IconGeneral
BrandDaikin
ModelFTYN50FV1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals