Removal of Electrical Box / PCBs / Swing Motors Si04-855
14 Removal Procedure
4. Remove the swing motor
for vertical blades.
Some models have no swing
motor for vertical blades.
1
Remove the swing shaft
on the right side.
Remove the swing shaft.
2
Remove the 2 screws
and detach the swing
motor assembly.
3
Remove the 2 screws
and remove the swing
motor.
The assembly has 6 hooks.
Step Procedure Points
(R2789)
(1) Unfasten the hook.
(2) Pull out the swing shaft.
(R12896)
Swing motor assembly
(R2791)
Hook
Hook
Swing motor