EasyManua.ls Logo

Daikin FWMT Series User Manual

Daikin FWMT Series
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TECHNICAL MANUAL
Chilled Water Fan Coil Units
FWMT, FWMJC(C), FWKE, FWPMM, UAHMM Series
FWMT FWMJC/FWKE
FWMJCC
FWPMM
UAHMM
TM-FCU-W-SG-A3
Question and Answer IconNeed help?

Do you have a question about the Daikin FWMT Series and is the answer not in the manual?

Daikin FWMT Series Specifications

General IconGeneral
ModelFWMT Series
Voltage220-240V
ConfigurationWall-mounted
AirflowVaries by model
Power ConsumptionVaries by model
Noise LevelVaries by model
WeightVaries by model
Dimensions (W x H x D)Varies by model
Frequency50Hz

Summary

Nomenclature

Product Type and Model Codes

Explains the coding for different product types and their models.

Size, Revision, and Power Supply

Details unit size, revision number, and power supply specifications.

Product Series Identification

Identifies the different product series (A, B, C, E) for the units.

Product Line-Up

Model Classification and Features

Lists models with PCB, handset, control, connection, air discharge, and filter options.

Application Information

Operating Limits for FWMT, FWMJCC, FWMJC & FWKE, FWPMM

Specifies temperature and pressure limits for cooling and heating modes.

Operating Limits for UAHMM

Details the operational temperature and pressure boundaries for UAHMM units.

Installation Guide

System Configuration and Jumper Settings

Explains jumper settings for heatpump/cooling modes and valve applications.

Controller Board Options and Modes

Explains Unoccupied, Anti Freeze, Window Open, and Load Shedding modes.

Sound Data

Sound Pressure Level Measurements

Provides sound pressure level (dBA) data across different frequencies and speeds.

Sound Power Level Measurements

Presents sound power level (dB, reference 1pW) data across frequencies.

NC Curve Analysis

Displays Noise Criteria (NC) curves for various models and speeds.

Selection Process

Pulley Data and Motor Specifications

Summarizes pulley center distance, motor size, and RPM for UAHMM series.

Fan Performance Chart

Fan Performance Curves

Illustrates fan performance (air flow vs. external static pressure) at different speeds.

Engineering & Physical Data

Unit Specifications and Capacities

Provides cooling/heating capacities, power, air flow, and water flow data.

Fan and Motor Data

Details fan speed, efficiency, motor output, and efficiency ratings.

Coil, Filter, and Casing Specifications

Lists material specifications for coils, filters, and casing details.

Outlines & Dimensions

FWMT Series Dimensions

Provides dimensional drawings and measurements for FWMT indoor units.

FWMJC/FWKE Series Dimensions

Shows dimensional data for FWMJC and FWKE ceiling cassette units.

FWMJCC Series Dimensions

Presents dimensional drawings for FWMJCC ceiling cassette units.

FWPMM Series Dimensions

Details physical dimensions for FWPMM concealed and ducted units.

UAHMM Series Dimensions

Provides dimensional drawings for UAHMM ducted units.

Wiring Diagrams

FWMT Series Wiring Diagram

Illustrates the electrical connections for FWMT models.

FWMJC/FWKE/FWPMM Series Wiring Diagrams

Shows wiring schematics for FWMJC, FWKE, and FWPMM models.

UAHMM Series Wiring Diagrams

Displays electrical connection diagrams for UAHMM models.

Service & Maintenance

Maintenance Procedures and Schedule

Outlines recommended checks and cleaning for unit components.

Troubleshooting

Self-Diagnostic Tables

Lists fault indications, error codes, and recommended actions for self-diagnostics.