Loading...
3 | Components
Service manual
153
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
ab
a Insulation
b Main PCB
2 Disconnect all connectors from the main PCB.
3 Disconnect the electrical power supply wiring from the wire terminals.
f
a
d
c
b
e
a Electrical power supply wiring
b Wire terminals
c Screws
d Wire clamp
e Screws
f Right side plate assembly
4 Remove the screws that fix the wire clamp.