Loading...
6 | Technical data
Service manual
242
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
6.4 Component overview
6.4.1 Component overview: Outdoor unit
RXM20~35R + ARXM25~35R
i
j
k
l
mo
p
a
b
c
de
f
g
n
h
a Air thermistor R1T i Main PCB A1P
b Heat exchanger j Power supply terminal X1M
c Heat exchanger thermistor R2T k Expansion valve Y1E
d Muffler with filter l Muffler
e Stop valve with service port (gas) m Accumulator
f Stop valve (liquid) n Compressor M1C
g 4‑way valve Y1S o Discharge pipe thermistor R3T
h Fan motor M1F p Fan

Table of Contents