6 | Technical data
Service manual
243
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
RXM42~71R + ARXM50~71R
j
k
m
oq
r
a
b
c
de
f
g
p
h i
l
n
m
m
a Air thermistor R1T j Main PCB A1P
b Heat exchanger k Power supply terminal X1M
c Heat exchanger thermistor R2T l Muffler
d Liquid receiver m Expansion valve Y1E
e Stop valve with service port (gas) n Muffler with filter
f Stop valve (liquid) o Accumulator
g 4‑way valve Y1S p Compressor M1C
h Fan motor M1F q Discharge pipe thermistor R3T
i High pressure switch S1PH r Fan