3 | Components
Service manual
122
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
3.11.2 Repair procedures
To remove the intelligent eye sensor
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see "3.14Plate work"[4151].
1 Remove the control panel from the indoor unit.
a Control panel
b Intelligent eye sensor PCB
2 Disconnect the connector from the intelligent eye sensor PCB.
3 Carefully click the complete intelligent eye sensor PCB out of the indoor unit.
4 To install the intelligent eye sensor PCB, see "Repair procedures"[4122].
To install the intelligent eye sensor
1 Click the intelligent eye sensor PCB on the indoor unit.
a Control panel
b Intelligent eye sensor PCB
2 Connect the harness to the intelligent eye sensor PCB.
3 Install the control panel on the indoor unit.
Is the problem solved? Action
Yes No further actions required.