3 | Components
Service manual
173
RXM20~71R + ARXM25~71R + FTXM20~71R + ATXM25~50R +
FVXM25~50A
Split New Perfera R32
ESIE20-11 – 2021.01
b
a
cd
a Swing flap
b Screw (swing flap motor fixation)
c Swing flap motor
d Coupling piece
5 Remove the swing flap motor from the coupling piece.
6 To install the swing flap motor, see "Repair procedures"[4172].
To install the swing flap motor
1 Install the coupling piece on the swing flap motor.
2 Install the swing flap motor in the correct location on the indoor unit.
b
a
cd
a Swing flap
b Screw (swing flap motor fixation)
c Swing flap motor
d Coupling piece
3 Install and tighten the screw to fix the swing flap motor.
4 Install the swing flap.
5 Install the swing raster motor, see "Repair procedures"[4182].
6 Install the switch box, see "3.14Plate work"[4151].